This study investigated the seismic performance of a hybrid damper composed of a steel slit plate and friction pads, and an optimum retrofit scheme was developed based on life cycle cost. A sample hybrid damper was tested under cyclic loading to confirm its validity as a damping device and to construct its nonlinear analysis model. The effectiveness of the optimum damper distribution schemes was investigated by comparing the seismic fragility and the life cycle costs of the model structure before and after the retrofit. The test results showed that the damper behaved stably throughout the loading history. Numerical analysis results showed that the slit-friction hybrid dampers optimally distributed based on life cycle cost proved to be effective in minimizing the failure probability and the repair cost after earthquakes.
机译:本研究研究了由钢切片板和摩擦垫组成的混合阻尼器的地震性能,并且基于生命周期成本开发了最佳改装方案。 在循环负载下测试样品混合阻尼器以确认其有效性作为阻尼装置,并构建其非线性分析模型。 通过比较改装前后模型结构的地震脆性和生命周期成本来研究最佳阻尼分布方案的有效性。 测试结果表明,在整个装载历史中,阻尼器稳定地表现得稳定。 数值分析结果表明,基于生命周期成本最佳地分布的狭缝摩擦混合阻尼器在最小化地震后最小化故障概率和修复成本方面是有效的。