A Prestressed stayed steel column is an efficient and lightweight way with regard to enhancing the stability behaviour of a compression column. In the past, researchers primarily concentrated on investigating the behaviour of stayed steel columns with horizontal crossarms. However, this article focuses on prestressed stayed steel columns with split-up crossarm system, in which the crossarms are aslant and rotational symmetrically arranged. A mathematical formula calculating the optimal pretension that corresponds to the maximum critical buckling load was established according to geometric analysis based on the small deformation assumption. It was demonstrated that critical buckling mode of this stayed column is different from the one with horizontal crossarms. The governing imperfection direction that should be adopted in the nonlinear buckling analysis was determined in this work. In addition, the effects of crossarm inclination, stay diameter, and crossarm length on the stability behaviour were investigated An influencing factor denotes the ratio of the load carrying capacity of the prestressed stayed steel column to the Euler load of the main column was also obtained.
机译:预应力留钢柱是一种高效而轻巧的方式,有助于提高压缩柱的稳定性行为。在过去,研究人员主要集中在调查与水平横虫的留钢柱的行为。但是,本文重点侧重于预应力留钢柱,分裂横梁系统,其中横梁是对称的对称排列的斜体和旋转。根据基于小变形假设的几何分析,建立了根据基于小变形假设的几何分析来建立对应于最大关键屈曲负荷的最佳预照的数学公式。据证明,这种留柱的关键屈曲模式与具有卧式横刀的临界模式不同。在这项工作中确定了在非线性屈曲分析中应采用的控制缺陷方向。另外,研究了横梁倾斜,直径和横梁长度对稳定性行为的影响,影响了将预应力留钢柱的负载承载能力与主柱的欧拉负荷的比率表示的影响因子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号