首页> 外文期刊>Thin-Walled Structures >Buckling and collapse capacity of prestressed steel tube stayed columns with one and two crossarms
【24h】

Buckling and collapse capacity of prestressed steel tube stayed columns with one and two crossarms

机译:一两个横臂的预应力钢管斜柱的屈曲和塌陷能力

获取原文
获取原文并翻译 | 示例
           

摘要

Prestressed tube stayed columns with one and two crossarms are investigated. The analyses are performed using SCIA Engineer software and ANSYS package and validated by tests of four stayed columns. First, the investigations concern the ideal (perfect) columns and cover linear buckling analyses (LBA) and geometrically nonlinear analyses (GNIA) to obtain critical loads and buckling modes under various prestressing levels. Second, the collapse loadings of the imperfect columns with initial deflections required by Eurocode EN 1993-1-1 are analysed with respect to relevant initial deflection modes and material behaviour (elastic for mild steel, nonlinear for stainless steel). All the analyses are performed for geometrical characteristics of the tested columns and the results concerning both the column with one or two crossarms are set against each other to assess the respective effectivity. In addition, the geometrical analysis of the prestressed ideal column with two crossarms and respective formulas concerning optimal prestressing and maximal critical loading are presented. Finally some recommendations for practical use are suggested.
机译:研究了带有一个和两个横臂的预应力管撑柱。使用SCIA Engineer软件和ANSYS软件包进行分析,并通过对四个斜柱的测试进行验证。首先,研究涉及理想(完美)柱,并涵盖了线性屈曲分析(LBA)和几何非线性分析(GNIA),以获得在各种预应力水平下的临界载荷和屈曲模式。其次,针对相关的初始挠度模式和材料性能(低碳钢为弹性,不锈钢为非线性),分析了欧洲规范EN 1993-1-1要求的具有初始挠度的不完善柱的坍落荷载。进行所有分析以分析被测色谱柱的几何特性,并将具有一个或两个横臂的两个色谱柱的结果相对设置,以评估各自的有效性。此外,还介绍了带有两个横臂的预应力理想柱的几何分析以及有关最佳预应力和最大临界载荷的公式。最后,提出了一些实用建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号