...
首页> 外文期刊>Separation and Purification Technology >Purification of concentrated nickel sulfuric liquors via synergistic solvent extraction of calcium and magnesium using mixtures of D2EHPA and Cyanex 272
【24h】

Purification of concentrated nickel sulfuric liquors via synergistic solvent extraction of calcium and magnesium using mixtures of D2EHPA and Cyanex 272

机译:使用D2ehpa和Cyanex 272的混合物通过协同溶剂萃取钙和镁的浓缩镍硫萃取纯化

获取原文
获取原文并翻译 | 示例
           

摘要

A synergistic solvent extraction circuit consisting of D2EHPA and Cyanex 272 was applied to purify a concentrated Ni sulfuric solution ([Ni] = 88 g L-1 [Mg] = 3.1 g L-1, [Ca] = 0.5 g L-1) similar to the MHP industrial liquors that feed the electrowinning step. The temperature was identified as a key parameter to optimize Mg extraction as well as to promote the selective recovery of co-extracted Ni in the extraction stages and make the stripping of Ca feasible using HCl as a stripping agent. Ca was crowded out by Ni from the loaded D2EHPA + Cyanex 272 solution and limited the operating pH range between 2 and 4. Under optimum conditions, 98.0% Ca and 98.4% Mg were simultaneously extracted in two and three theoretical stages by D2EHPA (0.30 M) + Cyanex 272 (0.32 M) mixture (pH 4, A/O ratio = 0.7 and 50 degrees C). Co-extracted Ni was selectively recovered (99.7%) from the loaded D2EHPA + Cyanex 272 using [H2SO4) = 0.063 M in three stages (O/A ratio = 1 and 50 degrees C). Ca and Mg can be completely stripped out from the loaded D2EHPA + Cyanex 272 at 50 degrees C in only 1 ([HCl] = 3 M, O/A ratio = 5) or two theoretical stages ([H2SO4] = 1 M, O/A ratio = 2). The purified liquor containing 80 g L-1 Ni (99.9% purity) can be directed for the electrowinning step to produce Ni cathodes. Extraction and stripping kinetics are rapid (equilibrium reached within 5 min). Thermodynamic analysis was done to support the synergism/antagonism trends observed experimentally.
机译:应用由D2ehPa和Cyanex 272组成的协同溶剂萃取电路,纯化浓缩的Ni硫酸溶液([Ni] = 88g L-1 [Mg] = 3.1g L-1,[Ca] = 0.5g L-1)类似于MHP工业液体,其喂养电滤送步骤。将温度鉴定为优化Mg提取的关键参数,以及促进提取阶段中共提取的Ni的选择性恢复,并使用HCl作为汽提剂的可行剥离。通过从负载的D2ehpa + cyanex 272溶液中挤出Ni,并限制在2和4之间的操作pH范围。在最佳条件下,通过D2ehPa的两点和三个理论阶段同时提取98.0%Ca和98.4%Mg(0.30米)+氰基272(0.32μm)混合物(pH 4,A / O比率= 0.7和50℃)。使用[H 2 SO 4)在三个阶段(O / A比率= 1和50℃)中选择性地回收来自负载的D2ehPA + Cyanex 272的共萃取的Ni(99.7%)(99.7%)。在仅1([HCl] = 3M,O / A比率= 5)或两个理论阶段([H2SO4] = 1米,o / a比率= 2)。含有80gL-1 Ni(99.9%纯度)的纯化液可以针对电环宁步骤以产生Ni阴极。提取和剥离动力学快速(5分钟内达到平衡)。进行热力学分析以支持实验所观察到的协同性/拮抗趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号