摘要

Purpose: To assess diagnostic consistency and relation between spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP) in patients with primary open-angle glaucoma (POAG). Methods: This retrospective study comprised 51 eyes of 51 patients with a confirmed diagnosis of POAG. The qualitative and quantitative SD-OCT parameters (retinal nerve fiber layer thicknesses [RNFL; average, superior, inferior, nasal and temporal], RNFL symmetry, rim area, disc area, average and vertical cup/disc [C/D] ratio and cup volume) were compared with parameters of SAP (mean deviation, pattern standard deviation, visual field index, and glaucoma hemifield test reports). Results: Fifty-one eyes of 51 patients with POAG were recruited. Twenty-nine eyes (56.9%) had consistent RNFL and visual field (VF) damage. However, nine patients (17.6%) showed isolated RNFL damage on SD-OCT and 13 patients (25.5%) had abnormal VF test with normal RNFL. In patients with VF defect, age, average C/D ratio, vertical C/D ratio, and cup volume were significantly higher and rim area was lower when compared to those of the patients with normal VF. In addition to these parameters, worsening in average, superior, inferior, and temporal RNFL thicknesses and RNFL symmetry was significantly associated with consistent SD-OCT and SAP outcomes. Conclusions: In routine practice, patients with POAG can be manifested with inconsistent reports between SD-OCT and SAP. An older age, higher C/D ratio, larger cup volume, and lower rim area on SD-OCT appears to be associated with detectable VF damage. Moreover, additional worsening in RNFL parameters might reinforce diagnostic consistency between SD-OCT and SAP.
机译:目的:评估诊断一致性和频谱域光学相干断层扫描(SD-OCT)和标准自动围绕(SAP)的诊断一致性和初级开放角度荧光眼(POAG)患者的标准自动围绕(SAP)。方法:该回顾性研究包括51只患者的51名患者,确诊的POAG诊断。定性和定量的SD-OCT参数(视网膜神经纤维层厚度[RNFL;平均,优越,劣等,鼻腔和颞段],RNFL对称性,轮辋区域,盘区域,平均和垂直杯/盘[C / D]比率将杯体积)与SAP的参数进行比较(平均偏差,图案标准偏差,视野指数和青光眼升降试验报告)。结果:招募了51例POAG患者的五十一眼。二十九只眼(56.9%)一致的RNFL和视野(VF)损坏。然而,九名患者(17.6%)显示出SD-OCT和13名患者(25.5%)的分离的RNFL损伤,具有正常的RNFL的VF试验异常。在VF缺陷的患者中,与患者的患者的患者相比,在VF缺陷缺损患者中显着更高,垂直的C / D比和杯体积显着较高,并且轮辋区域较低。除了这些参数之外,平均值,优异的,较差和时间RNFL厚度和RNFL对称性的恶化与一致的SD-OCT和SAP结果显着相关。结论:在常规实践中,POAG患者可以表现出SD-OCT和SAP之间的不一致报告。较旧的C / D比,较大的C杯体积,较大的SD-OCT上的下轮廓区域似乎与可检测的VF损坏相关。此外,RNFL参数中的额外恶化可能会加强SD-OCT和SAP之间的诊断一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号