Light activation is an important clinical step for achieving success in restorative procedures. This study evaluated the influence of beam profile from different light emission tip types of multiwave light-emitting diodes (LEDs) on the curing profile of resin-based composites. Experimental composites were produced containing either camphorquinone (CQ) or diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide (TPO) as a photoinitiator. Multiwave LEDs with either a bundle light guide tip (Bluephase G2, Ivoclar Vivadent) or a microlens tip (VALO Cordless, Ultradent) were characterized using a beam profiler. Block-shaped samples (5X5X3 mm depth) of the two composites were cured in a custom-designed mold with the multiwave LEDs positioned to compare the regions exposed to the 420-495 nm (blue) and 380-420 nm (violet) emittances. To map the curing profile, the degree of conversion (DC) of longitudinal thin cross sections from each block was evaluated using transmission FT-NIR. Radiant exposure transmitted through the composites during curing was evaluated at different thicknesses. Data were analyzed using analysis of variance and Tukey test (alpha=0.05; ''beta=0.2). The results indicated that there were differences in the beam profile and the overall radiant exposures transmitted through the composites using each multiwave LED (p<0.01, df=1 F=73.18). However, there were no differences in the curing profiles provided by the two multiwave LEDs (p=0.89, df=12 F=0.52), and similar effects were found according to the different LED emittance regions (p =0.09, df=5, F=2.11). When considering up to 1 mm in depth, no differences in the DC were found between the composites containing either photoinitiators. Starting at 2 mm in depth, the composite containing TPO showed a decrease in DC in the 420-495 nm emittance region, while the composite containing CQ showed a similar decrease in cure efficiency only at 3-mm depth under both 380-420 nm and 420-495 nm emittance regions. Thus, despite the fact that the nonuniform light beam emitted from the two multiwave LEDs was visually distinctly different when delivering 24 J/cm(2), this difference did not seem to affect the curing profile of the composites. However, light transmission within 380-420 nm seems to be reduced with depth, directly affecting the curing profile of composites containing a photoinitiator with absorbance falling within this emission range.
机译:光活化是在恢复程序中实现成功的重要临床步骤。该研究评估了梁轮廓从不同发光尖端类型的多波发光二极管(LED)的影响在树脂基复合材料的固化型材上的影响。制备实验复合材料,其含有樟脑(CQ)或二苯基(2,4,4,6-三甲基苯甲酰基)膦氧化膦(TPO)作为光引发剂。使用光束分析器表征具有束光导尖端(Bluephase G2,IVOClar Vieverte)或微透镜尖端(VALO无绳,Ultradent)的多波LED。两种复合材料的块状样品(5×5x3mm深度)在定制设计的模具中固化,该模具定位成比较暴露于420-495nm(蓝色)和380-420nm(紫色)发射的区域。为了映射固化轮廓,使用变速器FT-NIR评估每个块的纵向薄截面的转换程度(DC)。通过在固化过程中通过复合材料传递的辐射暴露在不同的厚度下评估。使用方差分析和Tukey Test分析数据(alpha = 0.05;''beta = 0.2)。结果表明,光束轮廓有差异,并且使用每个多波LED通过复合材料传输的整体辐射曝光(P <0.01,DF = 1 f = 73.18)。然而,两个多波LED提供的固化曲线没有差异(P = 0.89,DF = 12 f = 0.52),并且根据不同的LED辐射区域发现类似的效果(P = 0.09,DF = 5, f = 2.11)。当深度达到1mm时,在含有光引发剂的复合材料之间没有发现DC的差异。从2mm开始,含有TPO的复合材料在420-495nm的辐射区域中显示出DC的降低,而含有CQ的复合材料显示在380-420nm和380-420nm以下的3mm深度下的固化效率类似地降低。 420-495 nm辐射区。因此,尽管在递送24J / cm(2)时,从两个多波LED发射的非均匀光束在视觉上明显不同,但这种差异似乎没有影响复合材料的固化曲线。然而,380-420nm内的光传输似乎在深度中减少,直接影响含有光引发剂的复合材料的固化曲线,其吸光度落在该发射范围内。

著录项

  • 来源
    《Operative dentistry》 |2019年第4期|共14页
  • 作者单位

    Univ Estadual Campinas Piracicaba Dent Sch Dept Restorat Dent Piracicaba SP Brazil;

    Univ Estadual Campinas Piracicaba Dent Sch Dept Restorat Dent Piracicaba SP Brazil;

    Univ Estadual Campinas Piracicaba Dent Sch Dept Restorat Dent Piracicaba SP Brazil;

    Oregon Hlth &

    Sci Univ Dept Restorat Dent Sch Dent Portland OR 97201 USA;

    Univ Estadual Campinas Piracicaba Dent Sch Dept Restorat Dent Piracicaba SP Brazil;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 口腔科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号