首页> 外文期刊>Ophthalmologica: International Journal of Ophthalmology=Journal International d'Ophtalmologie >Predictors of Photographic Quality with a Handheld Nonmydriatic Fundus Camera Used for Screening of Vision-Threatening Diabetic Retinopathy
【24h】

Predictors of Photographic Quality with a Handheld Nonmydriatic Fundus Camera Used for Screening of Vision-Threatening Diabetic Retinopathy

机译:使用手持式非丁基眼底相机的摄影质量的预测因素用于筛选视力威胁的糖尿病视网膜病变

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Purpose: To analyze predictors of image quality for a handheld nonmydriatic fundus camera used for screening of vision-threatening diabetic retinopathy. Methods: An ophthalmic photographer at an Aravind Eye Hospital obtained nonmydriatic and mydriatic fundus images from 3 fields in 275 eyes of 155 participants over 13 months using a Smart-scope camera (Optomed, Oulu, Finland) and a Topcon table-top fundus camera (Topcon, Tokyo, Japan). Two fellowship-trained retina specialists graded the images. Repeated-measures logistic regression assessed predictors of the main outcome measure: gradability of the fundus images. Results: Of 2,475 images, 76.2% of the Smartscope nonmydriatic images, 90.1% of the Smartscope mydriatic images, and 92.0% of the Topcon mydriatic images were gradable. Eyes with vitreous hemorrhage (OR = 0.24, p < 0.0001) or advanced cataract (OR = 0.08, p < 0.0001) had decreased odds of image gradability. Excluding eyes with cataract or vitreous hemorrhage, nonmydriatic macular image gradability improved from 68.4% in the first set of 55 eyes to 94.6% in the final set of 55 eyes. Conclusion: With sufficient training, paraprofessional health care staff can obtain high-quality images with a portable nonmydriatic fundus camera, particularly in patients with clear lenses and clear ocular media. (C) 2017 S. Karger AG, Basel
机译:目的:分析用于筛选视力威胁性糖尿病视网膜病变的手持非丁基眼底相机的图像质量的预测因子。方法:Aravind Eye医院的眼科摄影师在13个月内从275只参加者的3个领域获得了来自3个田地的非酰亚胺和散瞳眼底图像,超过13个月,使用智能范围相机(Optimed,Oulu,芬兰)和Topcon台式眼底相机( Topcon,东京,日本)。训练有素的retina专家培训了图像。重复措施后勤回归评估了主要结果措施的预测因子:眼底图像的渐变性。结果:2,475个图像,76.2%的SmartScope非不同的图像,90.1%的SmartScope Mydriatic图像,92.0%的Topcon Mydriatic图像渐变。眼睛具有玻璃体出血(或= 0.24,P <0.0001)或高级白内障(或= 0.08,P <0.0001)的图像渐变性的几率降低。不包括白内障或玻璃体出血的眼睛,非丁基黄斑图像的渐变性从68.4%提高了第一个55只55只眼睛的最终55只55只眼睛的94.6%。结论:培训足够的培训,Paraprofestional Mealth Care员工可以获得具有便携式非丁基眼底照相机的高质量图像,特别是在透明镜片和清晰的眼部介质的患者中。 (c)2017年S. Karger AG,巴塞尔

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号