This article describes a method for testing of the efficiency of the biological shielding of the hot cell facility, which were constructed as a part of the project SUSEN. Ten hot cells and one semi-hot cell are present in the facility Radiochemistry II. The shielding is made from steel plates. In order to demonstrate sufficient efficiency of the biological shielding of the hot cells and a correspondence between measured and contractual values at selected points. The test was done using sealed high activity (6o)co sources. The results are also used as a proof of the optimization of radiation protection for the workplace of this type. The results confirm significant optimization of radiation protection at the workplace. The dose received by a staff do not exceed one tens of annual limit during active service. Obtained results fulfill general requirements of radiation protection and will be used for further active service of hot cells facility.
机译:本文介绍了一种用于测试热细胞设施的生物屏蔽效率的方法,其被构造为项目酵素的一部分。 设施放射化学II中存在十个热细胞和一个半热电池。 屏蔽由钢板制成。 为了证明热电池的生物屏蔽的足够效率和所选点的测量和合同值之间的对应关系。 使用密封的高活性(60)Co来源进行该测试。 结果也用作这种类型工作场所优化辐射保护的证据。 结果证实了在工作场所辐射保护的显着优化。 工作人员收到的剂量在活动服务期间不超过一年年度限额。 获得的结果满足辐射保护的一般要求,将用于进一步的热细胞设施的活跃服务。