Thermoluminescence data for several materials show that there are measurable differences between signals from crystalline and powder variants. With examples starting with crystalline calcite, Iceland Spar, and aragonite, and calcium fluoride (with rare earth impurities) the crushed material has altered signals. The changes are variously (i) alterations in the relative intensities of the glow peaks, (ii) modifications of the emission spectra, (iii) higher intensity per unit weight from the powdered material and (iv) examples with different numbers of peaks. (v) Whilst the thermoluminescence peaks sometimes appear at lower temperatures, which is consistent with features (i) to (iv), caution is required as there can be experimental reasons which also result in lowered temperatures. These include altered thermal coupling and/or temperature gradients at the sample heater. The scale of potential experimental variations is surprisingly large, and they have relevance to all thermoluminescence studies. Examples of such effects have been noted and new suggestions to minimise them are presented.
机译:几种材料的热辐发光数据表明,来自晶体和粉末变体的信号之间存在可测量的差异。通过用晶圆石的实例,冰岛翼梁和金属石和氟化钙(具有稀土杂质),破碎的材料具有改变的信号。该变化是不同(i)辉光峰的相对强度的改变,(ii)从粉末材料和(iv)实施例,具有不同数量的峰值的实施例,发射光谱的相对强度,(iii)的较高强度。 (v)虽然热致发光峰值有时出现在较低温度下,其与特征(i)至(iv)一致,但需要小心,因为可以有实验原因也导致温度降低。这些包括在样品加热器处改变的热耦合和/或温度梯度。潜在的实验变化的规模令人惊讶地大,并且它们与所有热致发光研究有关。已经注意到这种效果的示例,并提出了最小化它们的新建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号