首页> 外文期刊>Research quarterly for exercise and sport >The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players
【24h】

The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players

机译:30-15间歇性健康测试:可靠,有效和有用的工具,以评估女性篮球运动员的有氧能力

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The purpose of this study was to determine the reliability, validity, and usefulness of 30?15 Intermittent Fitness Test (30-15(IFT)) in female basketball players. Methods: Nineteen female basketball players (17.82 ? 1.94 yr, 175.4 ? 7.3 cm, 67.9 ? 7.7 kg) competing in the National Croatian League performed one trial of a continuous treadmill running test and two trials of the 30-15(IFT). The 30-15(IFT) involves 30-s runs across a 40-m course interspersed with 15 s of walking, with running speed increasing every 45 s. The continuous treadmill running test was used as the criterion for validation. Results: High to very high reliability across test?retest trials were observed for maximal oxygen uptake (VO(2)max) (CV = 4.9%, ICC = 0.85), the 30-15(IFT) end-running velocity (V-IFT) (CV = 6.0%, ICC = 0.85), and maximal heart rate (HRmax) (CV = 4.8%, ICC = 0.96). Criterion validity was supported for the 30-15(IFT) with strong to very strong relationships with VO(2)max (r =0.69), V-IFT (r =0.74), and HRmax (r =0.73) attained during the continuous treadmill running test. The typical error (TE) of the 30-15(IFT) was greater than the smallest worthwhile change for VO(2)max (1.16 > 0.42 ml/kg/min), V-IFT (0.56 > 0.20 km/h), and HRmax (2.15 > 1.89 bpm) adjudging usefulness of the test as marginal. The TE of 0.56 km/h (90% CI = 0.44?0.77 km/h) demonstrates changes in the performance of one to two stages (0.5?1.0 km/h) are meaningful. Conclusions: The 30-15(IFT) possesses acceptable reliability and validity to assess maximal aerobic fitness capacity in female basketball players. While the usefulness of the 30-15(IFT) was marginal, meaningful changes in performance consisted of only one to two stages. The present findings support the 30-15(IFT) as a practical testing option for basketball practitioners to assess fitness capacities in female players.
机译:目的:本研究的目的是确定女性篮球运动员30?15间歇性健身试验(30-15(IFT))的可靠性,有效性和有用性。方法:19岁母篮球运动员(17.82?1.94 YR,175.4?7.3厘米,67.9?7.7千克)在国家克罗地亚联赛中竞争,进行了一项连续跑步机运行试验和30-15(IFT)的两项试验的试验。 30-15(IFT)涉及30-S跨越40米的跑步穿插着15秒的步行,运行速度每45秒增加。连续跑步机运行测试用作验证的标准。结果:跨越测试的高度高度高,观察到最大氧吸收(VO(2)最大)(CV = 4.9%,ICC = 0.85),30-15(IFT)终端运行速度(V- IFT)(CV = 6.0%,ICC = 0.85)和最大心率(HRMAX)(CV = 4.8%,ICC = 0.96)。 30-15(IFT)支持标准有效性,强度与VO(2)MAX(r = 0.69),V-IFT(r = 0.74)的非常强大的关系,并且在连续期间获得的HRMAX(r = 0.73)跑步机运行测试。 30-15(IFT)的典型误差(TE)大于VO(2)MAX(1.16> 0.42ml / kg / min),V-IFT(0.56> 0.20 km / h)的最小值变化,和HRMAX(2.15> 1.89 BPM)将测试的有用性判断为边际。 0.56 km / h(90%ci = 0.44?0.77 km / h)的TE表现出一到两个阶段的性能的变化(0.5?1.0 km / h)有意义。结论:30-15(IFT)具有可接受的可靠性和有效性,以评估女性篮球运动员中最大的好氧健身能力。虽然30-15(IFT)的有用性是边缘,但性能的有意义变化仅包括一到两个阶段。本研究结果支持30-15(IFT)作为篮球从业者的实际测试选择,以评估女性球员的健身能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号