首页> 外文期刊>NDT & E International: Independent Nondestructive Testing and Evaluation >Quantitative assessment of bonding between steel plate and reinforced concrete structure using dispersive characteristics of lamb waves
【24h】

Quantitative assessment of bonding between steel plate and reinforced concrete structure using dispersive characteristics of lamb waves

机译:钢板钢板与钢筋混凝土结构粘接的定量评估

获取原文
获取原文并翻译 | 示例
           

摘要

The study provides a technique to quantitatively and quickly assess the debonding range between steel plate and substrates for concrete-filled steel tubular member (CFST member) or reinforced concrete (RC) structure strengthened by steel plate with epoxy as the bonding agent. The technique involves single test with a transducer 400 mm away from a mechanical impact source. The spectrogram of the signal is obtained by Short Time Fourier Transformation (STFT) and reassigning technique. Numerical and experimental studies were performed for two layered (steel + concrete) and three layered (steel + epoxy + concrete) composite plates containing debonding crack with different lateral sizes. The interfacial debonding is evaluated by a parameter derived from the group velocity profile of zero-order antisymmetric mode (A(0)) of the steel plate with substrates. Quantitative relationships between the parameter and defect ratio are established for two-layered and three layered composite plates containing partially delaminated crack. The effects of impact-sources, and the defect position related to the test line were also discussed.
机译:该研究提供了一种通过钢板作为粘合剂加强的混凝土填充钢管构件(CFST构件)或增强混凝土(RC)结构的钢板和基板之间的定量和快速评估钢板和基板之间的剥离范围的技术。该技术涉及单一测试,其距离机械冲击源400mm。信号的频谱图通过短时间傅里叶变换(STFT)和重新分配技术获得。对两个分层(钢+混凝土)和三层(钢+环氧+混凝土)复合板进行了数值和实验研究,其含有不同的横向尺寸的剥离裂缝。通过从具有基板的钢板的零阶反对子模式(A(0))的零级反对子模式(A(0))的组速度分布来评估界面剥离。为含有部分分层裂缝的两层和三层复合板建立了参数和缺陷比之间的定量关系。还讨论了冲击源的影响,以及与测试线相关的缺陷位置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号