...
首页> 外文期刊>Microscopy research and technique >The effects of intrinsic and extrinsic acids on nanofilled and bulk fill resin composites: Roughness, surface hardness, and scanning electron microscopy analysis
【24h】

The effects of intrinsic and extrinsic acids on nanofilled and bulk fill resin composites: Roughness, surface hardness, and scanning electron microscopy analysis

机译:内在酸对纳米填充物和散装填充树脂复合材料的影响:粗糙度,表面硬度和扫描电子显微镜分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The objective of this study was to examine the effects of extrinsic or intrinsic acids on nanofilled and bulk fill resin materials in vitro. A total of 90 disks were prepared using dental restorative material (Filtek Z350XT, GrandioSO, Filtek Bulk Fill, X-tra fil). Thirty disks of each material were sub-divided into three groups (n = 10) that were immersed for 7 days in deionized water (DW), 5% citric acid (CA-pH 2.1), or 0.1% hydrochloric acid (HCl-pH = 1.2). Surface hardness and roughness (stylus profilometer by R-a parameter) analysis were performed before and after immersion. Morphological changes were evaluated by scanning electron microscopy. The data were analyzed by two-way ANOVA and Tukey's test (alpha = 0.05). All tested materials did not show significant differences in the effects of the DW, CA, or HCl solutions on surface roughness (p = .368). Likewise, the hardness loss was not affected by the solutions tested (p = .646), but there was a difference in the resin type (p = .002). Filtek Bulk Fill resin hardness was less affected, while Filtek Z350XT and GrandioSO presented the most hardness loss after 7 days of solution immersion. In terms of this experimental study, the results demonstrate the effectiveness of the mechanical properties (roughness and hardness surface) of nanofilled and bulk fill resin materials to resist erosion from extrinsic and intrinsic acids, therefore being potential candidates for dental applications.
机译:本研究的目的是在体外检查外部或本粒酸对纳米填充和块状填充树脂材料的影响。使用牙科恢复材料(Filtek Z350XT,GrandioO,Filtek Bulk Fill,X-Trafel)制备共有90个磁盘。将每种材料的30个磁盘分为三组(n = 10),其在去离子水(DW)中浸渍7天,5%柠檬酸(Ca-pH 2.1)或0.1%盐酸(HCl-pH值= 1.2)。在浸入之前和之后进行表面硬度和粗糙度通过R-A参数的触控剂型尺寸仪分析。通过扫描电子显微镜评估形态学变化。通过双向ANOVA和TUKEY的测试分析数据(alpha = 0.05)。所有测试的材料都没有显示出DW,CA或HCl溶液对表面粗糙度溶液(P = .368)的效果的显着差异(P = .368)。同样地,硬度损失不受测试的溶液的影响(P = .646),但树脂类型的差异(p = .002)。 Filtek散装填充树脂硬度受到影响较小,而Filtek Z350XT和Grandioso在溶液浸泡7天后呈现最硬度损失。就该实验研究而言,结果证明了纳米填充和散装填充树脂材料的机械性能(粗糙度和硬度表面)的有效性,以抵抗外部酸的侵蚀,因此是牙科应用的潜在候选者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号