...
首页> 外文期刊>Magnetic resonance in medicine: official journal of the Society of Magnetic Resonance in Medicine >MRI‐based quantitative susceptibility mapping (QSM) and R2* mapping of liver iron overload: Comparison with SQUID‐based biomagnetic liver susceptometry
【24h】

MRI‐based quantitative susceptibility mapping (QSM) and R2* mapping of liver iron overload: Comparison with SQUID‐based biomagnetic liver susceptometry

机译:基于MRI的定量敏感性映射(QSM)和R2 *肝脏过载的映射:与基于鱿鱼的生物磁性肝脏感受测验法的比较

获取原文
获取原文并翻译 | 示例

摘要

Purpose We aimed to determine the agreement between quantitative susceptibility mapping (QSM)‐based biomagnetic liver susceptometry (BLS) and confounder‐corrected R2* mapping with superconducting quantum interference device (SQUID)‐based biomagnetic liver susceptometry in patients with liver iron overload. Methods Data were acquired from two healthy controls and 22 patients undergoing MRI and SQUID‐BLS as part of routine monitoring for iron overload. Magnetic resonance imaging was performed on a 3T system using a three‐dimensional multi‐echo gradient‐echo acquisition. Both magnetic susceptibility and R2* of the liver were estimated from this acquisition. Linear regression was used to compare estimates of QSM‐BLS and R2* to SQUID‐BLS. Results Both QSM‐BLS and confounder‐corrected R2* were sensitive to the presence of iron in the liver. Linear regression between QSM‐BLS and SQUID‐BLS demonstrated the following relationship: QSM‐BLS?=?(?0.22?±?0.11)?+?(0.49?±?0.05) · SQUID‐BLS with r 2 ?=?0.88. The coefficient of determination between liver R2* and SQUID‐BLS was also r 2 ?=?0.88. Conclusion We determined a strong correlation between both QSM‐BLS and confounder‐corrected R2* to SQUID‐BLS. This study demonstrates the feasibility of QSM‐BLS and confounder‐corrected R2* for assessing liver iron overload, particularly when SQUID systems are not accessible. Magn Reson Med 78:264–270, 2017. ? 2016 International Society for Magnetic Resonance in Medicine
机译:目的,我们旨在确定与肝脏铁过荷患者的超导量子干扰装置(Squid)基生物磁性肝脏感染术(BLS)和混淆校正R2 *映射的定量敏感性映射(QSM)和混淆校正R2 *映射。方法从两种健康对照和22例接受MRI和Squid-BLS的患者获得数据,作为铁过载的常规监测的一部分。使用三维多相梯度回波采集在3T系统上进行磁共振成像。估计该采集估算肝脏的磁性敏感性和肝脏R2 *。线性回归用于将QSM-BLS和R2 *的估计进行比较鱿鱼-BLS。结果QSM-BLS和混淆校正R2 *对肝脏中铁的存在敏感。 QSM-BLS和Squid-BL之间的线性回归展示了以下关系:QSM-BLS?=?(?0.22?±0.11)?+?(0.49?±0.05)·鱿鱼 - BLS与R 2?= 0.88 。肝脏R2 *和Squid-BLS之间的测定系数也是R 2?= 0.88。结论我们确定了QSM-BLS和混淆校正的R2 *与鱿鱼-BLs之间的强烈相关性。本研究展示了QSM-BLS和混淆校正R2 *用于评估肝脏铁过载的可行性,特别是当鱿鱼系统无法访问时。 MANG REAN MED 78:264-270,2017。 2016国际医学磁共振学会

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号