Comparison of anterior segment and lens biometric measurements in patients with cataract

机译:白内障患者前段和镜头生物测量的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose This study was performed to compare anterior ocular biometric measurements of deep-range swept-source anterior segment optical coherence tomography (AS-OCT) (CASIA2) versus short-range swept-source AS-OCT (CASIA SS-1000), ultrasonography (AL-4000), and Scheimpflug camera analysis (Pentacam and EAS-1000) in patients with cataract. Methods One hundred eighty-five eyes of 128 participants with mild refractive error or cataract were examined. The central corneal thickness (CCT), aqueous depth (AQD), and lens thickness were obtained. The repeatability of CASIA2 measurements was assessed. Results In patients with cataract, the CCT, AQD, lens thickness, and lens anterior curvature by CASIA2 showed high intraclass correlation coefficients (ICCs) of > 0.99. Conversely, measurements of the posterior part of the lens such as lens posterior curvature showed lower ICCs. The ICCs were higher in healthy young participants than in patients with cataract. The ICCs tended to be lower in patients with mild than dense cataract. There was no statistically significant difference in the CCT and AQD between the CASIA2 and CASIA SS-1000 or in the lens thickness measurements between the CASIA2 and AL-4000 and between the CASIA2 and EAS-1000. There was a significant linear correlation in the biometric measurements between the CASIA2 and the other instruments. Conclusion We evaluated the biometric measurements of the anterior eye segment by the CASIA2. The CASIA2 yielded results comparable with those of the CASIA SS-1000, ultrasonography, and Scheimpflug camera. However, mild cataract decreased the repeatability of measurements of the posterior part of the lens.
机译:目的本研究进行了比较深度扫掠源前段光学相干性断层摄影断层扫描(AS-OCT)(CASIA2)的前眼性生物测量值与短程扫描源AS-OCT(Casia SS-1000),超声检查( Al-4000),以及白内障患者的Scheimpflug相机分析(Pentacam和EAS-1000)。方法检查有128名参与者的一百八十五只有温和屈光误差或白内障的参与者。获得中心角膜厚度(CCT),水深(AQD)和透镜厚度。评估CASIA2测量的可重复性。结果对白内障患者,CCT,AQD,透镜厚度和CASIA2的透镜前曲线显示出高11099的高脑相关系数(ICC)。相反,镜片的后部的测量镜片后曲率如镜片后曲率显示出较低的ICC。在健康的年轻参与者中,ICCS比白内障患者更高。在轻度比致密白内障的患者中,ICC倾向于降低。 CCT和CASIA2和CASIA SS-1000之间的CCT和AQD在CASIA2和AL-4000之间以及CASIA2和EAS-1000之间的镜头厚度测量中没有统计学上显着差异。 CASIA2和其他仪器之间的生物测量中存在显着的线性相关性。结论我们评估了CASIA2的前眼段的生物测量。 CASIA2产生的结果与Casia SS-1000,超声检查和Scheimpflug相机相当。然而,温和的白内障降低了镜片后部测量的可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号