首页> 外文期刊>Ear and hearing. >A 'Goldilocks' Approach to Hearing Aid Self-Fitting: Ear-Canal Output and Speech Intelligibility Index.
【24h】

A 'Goldilocks' Approach to Hearing Aid Self-Fitting: Ear-Canal Output and Speech Intelligibility Index.

机译:助听器自配合的“金发姑娘”方法:耳环输出和语音清晰度指数。

获取原文
获取原文并翻译 | 示例
           

摘要

The objective was to determine self-adjusted output response and speech intelligibility index (SII) in individuals with mild to moderate hearing loss and to measure the effects of prior hearing aid experience. Thirteen hearing aid users and 13 nonusers, with similar group-mean pure-tone thresholds, listened to prerecorded and preprocessed sentences spoken by a man. Starting with a generic level and spectrum, participants adjusted (1) overall level, (2) high-frequency boost, and (3) low-frequency cut. Participants took a speech perception test after an initial adjustment before making a final adjustment. The three self-selected parameters, along with individual thresholds and real-ear-to-coupler differences, were used to compute output levels and SIIs for the starting and two self-adjusted conditions. The values were compared with an NAL second nonlinear threshold-based prescription (NAL-NL2) and, for the hearing aid users, performance of their existing hearing aids. All participants were able to complete the self-adjustment process. The generic starting condition provided outputs (between 2 and 8?kHz) and SIIs that were significantly below those prescribed by NAL-NL2. Both groups increased SII to values that were not significantly different from prescription. The hearing aid users, but not the nonusers, increased high-frequency output and SII significantly after taking the speech perception test. Seventeen of the 26 participants (65%) met an SII criterion of 60% under the generic starting condition. The proportion increased to 23 out of 26 (88%) after the final self-adjustment. Of the 13 hearing aid users, 8 (62%) met the 60% criterion with their existing hearing aids. With the final self-adjustment, 12 out of 13 (92%) met this criterion. The findings support the conclusion that user self-adjustment of basic amplification characteristics can be both feasible and effective with or without prior hearing aid experience.
机译:目的是确定具有轻度到中度听力损失的个人的自我调整输出响应和语音可明智性指数(SII),并测量先前助听援助经验的影响。十三个助听器用户和13名非用户,具有类似的组平均纯音阈值,聆成了一个男人所说的预处理和预处理的句子。从通用水平和频谱开始,参与者调整(1)总水平,(2)高频升压,(3)低频切割。在进行最终调整之前,参与者在初步调整后进行了演讲感知测试。三种自选参数以及各个阈值和实际耳对耦合器差异,用于计算起始和两个自调整条件的输出水平和SII。将这些值与基于NAL第二非线性阈值的处方(NAL-NL2)进行比较,并且对于助听器用户,其现有的助听器的性能。所有参与者都能够完成自我调整过程。通用起始条件提供了在NAL-NL2规定的那些下方的输出(2和8?KHz)和SIIs,其显着低于那些。这两组增加了SII与处方没有显着不同的值。助听器用户,但不是非用户,在参加语音感知测试后显着提高高频输出和SII。 26名参与者的十七个(65%)在通用起动条件下达到60%的SII标准。最终自我调整后,比例增加到26例(88%)。在13名助听器用户中,8名(62%)达到了现有的助听器的60%标准。随着最终的自我调整,13分的12个(92%)达到了这个标准。调查结果支持的结论是,用户对基本放大特性的自我调整可与或没有现有助听器经验的可行和有效。

著录项

  • 来源
    《Ear and hearing.》 |2019年第1期|共9页
  • 作者单位

    Audiology Division School of Speech Language and Hearing Sciences San Diego State University;

    Audiology Division School of Speech Language and Hearing Sciences San Diego State University;

    Audiology Division School of Speech Language and Hearing Sciences San Diego State University;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 耳鼻咽喉科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号