Experimental investigation on discharge coefficient, C-d, for high viscosity fluid through nozzles was carried out. The viscosity of the fluid used for the test ranged from 350 to 1500 mPa s. The length-to-diameter ratio of the nozzle, l/d and the ratio of nozzle diameter to pipe diameter ratios beta were used to investigate the influence of geometry on C-d. Results show a significant dependence of C-d on Re, l/d and beta ratio. An empirical correlation on the discharge coefficient was developed based on the data from this study which was also compared with data from other published studies. This correlation, with an R-squared value of 0.9541, was valid for nozzle sizes 10-20 mm and for Re between 1 and 200. C-d values obtained from experimental data, and those from the empirical correlation were compared, and a mean standard deviation of 0.0231 was obtained.
机译:进行了对通过喷嘴的高粘度流体的放电系数,C-D的实验研究。 用于测试的流体的粘度范围为350至1500MPa s。 使用喷嘴,L / D的长度到直径和管直径比率β的比例用于研究几何形状对C-D的影响。 结果显示C-D对RE,L / D和β比的显着依赖性。 基于来自该研究的数据开发了对放电系数的经验相关性,其与来自其他公开研究的数据进行比较。 具有0.9541的R线值的这种相关性对于喷嘴尺寸为10-20mm,并且在1和200之间的RE之间是有效的,并且比较了从实验数据获得的CD值,以及从经验相关的CD值,并且平均标准偏差 得到0.0231。