首页> 外文期刊>Engineering failure analysis >Analysis of a failure mechanism in parabolic troughs receivers due to bellows cap overirradiation
【24h】

Analysis of a failure mechanism in parabolic troughs receivers due to bellows cap overirradiation

机译:波纹管帽过度放射由于波纹管帽的抛物面槽接收器失效机制分析

获取原文
获取原文并翻译 | 示例
           

摘要

During the last years the number of broken tube receivers in parabolic-trough solar collectors was higher than expected in several commercial solar power plants and the failure events increased specially in winter. An exhaustive on field inspection of the broken glass envelopes and expansion bellows of the receivers (heat collecting elements) suggests that this unusual number of damaged receiver tubes is somewhere related with the over-irradiation of the bellows caps in some operation conditions. In this work the failure mechanism and the operation conditions that make it possible are analyzed. The analysis of this failure mechanism have allowed to identify the seasonality of the phenomenon and to design an appropriate strategy to reduce or even to prevent the failure due to the over irradiation of the bellows caps of solar receiver tubes.
机译:在过去几年中,抛物面 - 槽太阳能集热器的破碎管接收器的数量高于几个商业太阳能发电厂的预期,冬季故障事件特别增加。 在接收器(集热元件)的破碎玻璃包络和膨胀波纹管的野外检查方面令人彻默地检查了这种不寻常的损坏接收管是在某些操作条件下与波纹管盖的过度照射有关。 在这项工作中,分析了失败机制和使其成为可能的操作条件。 对这种故障机制的分析已经允许识别现象的季节性,并设计适当的策略以减少甚至防止由于过度照射太阳能接收管的波纹管盖而导致的故障。