FATALITY INVESTIGATION: Electric Power Lines and an Overgrown Tree Prove to Be a Deadly Combination

机译:死亡调查:电力线和过度的树木被证明是一种致命的组合

获取原文
获取原文并翻译 | 示例

摘要

It should have been a routine spring day. At approximately 9 a.m., a two-man crew from a tree-trimming company arrived at a private residence to clear out brush and trim a tree that was positioned next to a power line. The branches of the tree to be trimmed were growing in close proximity to an adjacent power line. However, both employees on the crew were line clearance tree trimmers who had received specialized training and were permitted to work the OSHA-man-dated minimum approach distance (MAD) of 10 ft. from energized power lines.
机译:它应该是常春藤春天的日子。 从一家树修剪公司的一个双人船员大约在上午9点到达私人住所以清除刷子并修剪一条位于电力线旁边的树。 要修剪的树的分支在相邻的电力线附近越来越大。 然而,船员上的两位员工都是接受专业培训的线间隙树修剪器,并被允许在10英尺的OSHA-MAN-DATED最低方法(MAD)上工作。从通电电源线。