首页> 外文期刊>International journal of mass spectrometry >Development and validation of a simple isotope dilution-liquid chromatography-tandem mass spectrometry method for detecting vitamins A and E in serum and amniotic fluid
【24h】

Development and validation of a simple isotope dilution-liquid chromatography-tandem mass spectrometry method for detecting vitamins A and E in serum and amniotic fluid

机译:一种简单同位素稀释液相色谱 - 串联质谱法的开发与验证用于检测血清和羊水中的维生素A和E.

获取原文
获取原文并翻译 | 示例

摘要

Accurate and simple measurements of vitamins A(all-trans retinol) and E(alpha.-tocopherol) are essential for ensuring the appropriate supplementation and diagnosis of diseases related to vitamin A or E deficiency. High-performance liquid chromatography is a widely used method; however, few studies have reported an isotope dilution-liquid chromatography tandem mass spectrometry method(ID-LC-MS/MS) for detecting vitamins A and E in serum, let alone amniotic fluid. Here, we developed and validated an accurate and precise measurement procedure based on ID-LC-MS/MS for detecting vitamins A and E in serum and amniotic fluid. In this method, only 50 mu L of serum/amniotic fluid was used. After simple protein precipitation and extraction, all-trans retinol and alpha-tocopherol were analyzed by ID-LC-MS/MS using positive electrospray ionization in multiple reaction monitoring mode. Vitamins A and E status was evaluated using the validated method in 65 apparently healthy volunteers and 58 pregnant women in the second trimester. The within-run and total coefficients of variation(CVs) of all-trans retinol were 2.8%-3.9% and 4.7%-6.0%, respectively, in serum; and 5.0%-7.3% and 5.4%-7.4%, respectively, in amniotic fluid ; and the values for alpha-tocopherol were 3.2%similar to 4.3% and 3.3% similar to 4.9% in serum and 6.2%-7.1% and 8.0%-9.1% in amniotic fluid. The accuracy bias of the ID-LC-MS/MS method was less than 5.0% for both all-trans retinol and alpha-tocopherol. Mean levels of all-trans retinol and alpha-tocopherol in the 65 apparently healthy volunteers were 0.504 +/- 0.126 mg/L and 12.038 +/- 2.501 mg/L, respectively. A significant positive correlation was observed between serum and amniotic fluid all-trans retinol (r=0.277, P=0.035) in the pregnant women in the second trimester, while no correlation with alpha-tocopherol (P=0.290). None of the volunteers developed vitamin A or E deficiency. In conclusion, an ID-LC-MS/MS method for measuring both serum and amniotic flu
机译:对维生素A(全反转视黄醇)和E(α-生育酚)的准确和简单测量对于确保适当的补充和诊断与维生素A或缺乏有关的疾病至关重要。高效液相色谱是一种广泛使用的方法;然而,很少有研究报告了同位素稀释 - 液相色谱串联质谱法(ID-LC-MS / MS),用于检测血清中的维生素A和E,更不用说羊水。在这里,我们基于ID-LC-MS / MS进行了精确和精确的测量过程,用于检测血清和羊水中的维生素A和E.在该方法中,使用50μl血清/刚性液体。在简单的蛋白质沉淀和提取后,通过在多重反应监测模式下使用正电喷雾电离通过ID-LC-MS / MS分析全反式视黄醇和α-生育酚。使用验证的方法在65中的验证方法评估了维生素A和E状态,显然是健康的志愿者和58名孕妇在妊娠早期的孕妇。在血清中,全反式视黄醇的局部变化和变异的总系数(CVS)分别为2.8%-3.9%和4.7%-6.0%;羊水分别为5.0%-7.3%和5.4%-7.4%; α-生育酚的值为3.2%,类似于4.3%和3.3%,血清中的4.9%,羊水中的4.9%-7.1%和8.0%-9.1%。对于全反式视黄醇和α-生育酚,ID-LC-MS / MS方法的精度偏压小于5.0%。 65中的全反式视黄醇和α-生育酚的平均水平显然是健康的志愿者分别为0.504 +/- 0.126 mg / L和12.038 +/- 2.501 mg / L.在孕妇在第二三个月的孕妇中血清和羊水全转醇(R = 0.277,P = 0.035)之间观察到显着的阳性相关性,同时与α-生育酚(P = 0.290)没有相关性。没有一个志愿者开发维生素A或缺乏症。总之,用于测量血清和羊毛流感的ID-LC-MS / MS方法

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号