首页> 外文期刊>International journal of nonlinear sciences and numerical simulation >Numerical Study of the Discharged Heat Water Effect on the Aquatic Environment from Thermal Power Plant by using Two Water Discharged Pipes
【24h】

Numerical Study of the Discharged Heat Water Effect on the Aquatic Environment from Thermal Power Plant by using Two Water Discharged Pipes

机译:用两条排水管道从热电厂排出热水效应的数值研究

获取原文
获取原文并翻译 | 示例
           

摘要

The paper presents a numerical study of the discharged heat water effect on the aquatic environment from the thermal power plant by using two water discharged pipes. It is solved by the Navier-Stokes and temperature transport equations for an incompressible fluid in a stratified medium. The aim of this study is to improve the existing water discharge system to reduce the heat load on the reservoir-cooler of the thermal power plants operation (Ekibastuz SDPP-1). In this study thermal pollution to the reservoir-cooler using only two water discharged pipes as so using the existing one and building only one additional in the eastern part of the reservoir- cooler is numerically simulated. The numerical method is based on the projection method which was approximated by the finite volume method. The numerical solution of the equation system is divided into four stages. The algorithm is parallelized on a high-performance computer. The obtained numerical results of three-dimensional stratified turbulent flow for two water discharged pipes of the thermal power plant were compared with experimental data and with numerical results for one water discharged pipe. General thermal load in the reservoir-cooler decreases comparing one water discharged pipe and revealed qualitatively and quantitatively approximately the basic laws of hydrothermal processes occurring in the reservoir-cooler can be seen that from numerical simulations where two water discharged pipes were used.
机译:本文通过使用两种排水管道,从热电厂的水生环境对水生环境的数值研究。它由Navier-Stokes和温度传输方程在分层介质中的不可压缩流体求解。本研究的目的是改善现有的排水系统,以减少热电厂操作的储存器上的热负荷(Ekibastuz SDPP-1)。在这项研究中,仅使用两个排水管的储层冷却器热污染,因此使用现有的管道,在储存器的东部额外建筑物,在数值上模拟。数值方法基于由有限体积法近似的投影方法。等式系统的数值解分为四个阶段。该算法在高性能计算机上并行化。与实验数据进行比较了用于热电厂的两个排水管的三维分层湍流的数值结果,并对一个排水管的数值结果进行了比较。储存冷却器中的一般热负荷减小了一个排水管,并定性地揭示了储存器冷却器中发生的水热过程的基本规律,可以看出,从使用两个排水管的数值模拟。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号