Concrete filled steel tubular (CFST) columns have gained much attention for their excellent structural properties. This paper focuses on fire resistance of concrete-filled square hollow section (SHS) corner columns, which are usually under biaxial loading and two-adjacent-side fire loading. The thermal field of those members is asymmetric and additional eccentricity and additional deflection would be induced, which eventually changes the behaviour of those columns. A two-step sequentially coupled analytical approach was developed to predict the thermal and structural behavior of concrete-filled SHS columns, which was verified by related experimental results and then utilized for parametric studies. The parameters include load ratio, cross-sectional dimension, slendemess ratio, load eccentricity, steel and concrete strength, etc. It's found that the load ratio, cross-sectional dimension, slendemess ratio and load eccentricity are principal factors affecting fire resistance of concrete-filled SHS columns under two-adjacent-side fire loading. Based on the results of parametric studies, a design formula was proposed for predicting fire resistance of concrete-filled SHS columns in two-adjacent-side fire.
机译:钢管混凝土(CFST)柱因其出色的结构性能而备受关注。本文着重研究通常在双轴荷载和两个相邻边火荷载下的方钢管混凝土空心柱(SHS)角柱的耐火性。这些构件的热场是不对称的,并且会引起额外的偏心率和额外的挠曲,最终改变了这些柱的性能。开发了一种两步顺序耦合分析方法来预测混凝土填充SHS柱的热和结构行为,并通过相关的实验结果进行了验证,然后将其用于参数研究。这些参数包括荷载比,横截面尺寸,滑移率,荷载偏心率,钢筋和混凝土强度等。发现荷载比,横截面尺寸,滑移率和荷载偏心率是影响混凝土耐火性的主要因素,在两边火力作用下填充了SHS柱。基于参数研究的结果,提出了一种设计公式,用于预测两边火灾中混凝土SHS柱的耐火性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号