Nowadays, advanced oxidation processes (AOPs) are receiving increasing attention to be used for industrial wastewater treatment. In this study, the wastewater of Shazand Oil Refinery Company in Iran was treated using photo-Fenton method as a branch of AOPs. Box-Behnken design was used to reduce the number of tests and to conduct the statistical analysis of the results. The aim of this study was to reduce the chemical oxygen demand (COD) of industrial wastewater and obtain the optimum condition in the removal of COD. For this purpose, the effects of operating factors such as hydrogen peroxide concentration (10-30 mM), iron ion concentration (0.7-2.1 mM), and pH (2-6) were investigated. The results of the analysis of variance showed that the operating parameters were effective. The initial COD of industrial wastewater was about 3400 mg l(-1), and in the achieved optimum conditions, approximately 75% of initial COD was removed and the amounts of other parameters such as biological oxygen demand (BOD), total organic carbon (TOC), and total dissolved solid were reduced significantly. The BOD5 to COD ratio of the treated wastewater was increased considerably. Moreover, the kinetic study revealed pseudo-first-order reactions for the removal of COD. Accordingly, as a figure of merit, the "electrical energy per order" was determined at 25.04 kWh m(-3) order(-1), showing low electrical energy consumption and high economical profit in comparison with high COD removal.
机译:如今,先进的氧化方法(AOP)正在接受越来越关注用于工业废水处理。在这项研究中,使用照片Fenton方法作为AOPS的分支,对伊朗的Shazand炼油厂公司废水。 Box-Behnken设计用于减少测试次数并进行结果的统计分析。本研究的目的是减少工业废水的化学需氧量(COD),并在去除COD中获得最佳条件。为此目的,研究了经运行因子(如氢过氧化氢浓度(10-30mm),铁离子浓度(0.7-2.1mm)和pH(2-6)的影响。方差分析结果表明,操作参数有效。工业废水的初始鳕鱼约为3400mg(-1),并且在实现的最佳条件下,除去约75%的初始鳕鱼,其他参数的量如生物需氧量(BOD),总有机碳( TOC)和总溶解的固体显着降低。处理废水的BOD5与COD比率相当大。此外,动力学研究揭示了用于去除COD的假一级反应。因此,作为优点的形象,在25.04kWh m(-3)阶(-1)时测定“电能”,显示出低电能消耗和高经济利润,与高COD移除相比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号