...
首页> 外文期刊>International journal of applied mechanics >Evaluation of corrosion resistance of Co-Cr alloys fabricated with different metal laser sintering systems
【24h】

Evaluation of corrosion resistance of Co-Cr alloys fabricated with different metal laser sintering systems

机译:用不同金属激光烧结系统制造的CO-CR合金耐腐蚀性的评价

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE. The aim of this study was to evaluate the corrosion resistance of the specimens produced by five different commercial metal laser sintering (MLS) systems with their recommended Co-Cr alloy powders. MATERIALS AND METHODS. The MLS machines and the alloy powders used were, ProX 100-ST2724G (St-Pro), Mysint 100-EOS SP2 (SP2-Mys), EOSINT 270-EOS SP2 (SP2-EOS), SLM 100-Starbond CoS (SB-SLM), and MLab Cusing-Remanium (R) Star (RS-MLab), respectively. Eight specimens from each group were prepared. Open circuit potential (E-ocp) and electrochemical impedance spectroscopy (EIS) measurements of polished surfaces of the specimens were conducted in a three-electrode cell using a potentiostat-galvanostat in Fusayama-Meyer artificial saliva (AS). Specimens from each group were immersed in AS and de-ionized water for seven days. E-ocp, charge transfer resistance (R-alpha) values, and released ions (mu g/cm(2) x 7d) in different solutions were determined. The specimen surfaces were observed with SEM/EDS. Results were analyzed statistically. RESULTS. E-ocp values have shifted to potentials that are more positive over time. Steady-state E-ocp values were from high to low as follows, SB-SLM, SP2-Mys, SP2-EOS, RS-MLab, and ST-Pro, respectively. After 60 mins, RS-MLab specimens had the highest R-alpha value, followed by SP2-Mys, SB-SLM, SP2-EOS, and ST-Pro. In all groups, ion release was higher in AS than that in de-ionized water. CONCLUSION. There were small differences among the corrosion resistances of the Co-Cr alloy specimens produced with MLS systems; meanwhile, the corrosion resistances were quite high for all specimens.
机译:目的。该研究的目的是评估由五种不同商业金属激光烧结(MLS)系统产生的试样的耐腐蚀性,其推荐的CO-CR合金粉末。材料和方法。使用的MLS机器和所用的合金粉末,Prox 100-ST2724G(ST-Pro),MySint 100-EOS SP2(SP2-MYS),EOSINT 270-EOS SP2(SP2-EOS),SLM 100-星朋COS(SB- SLM)和MLAB CUSING-REMANIUM(R)星(RAB)。每组八个标本制备。在Fusayama-Meyer人造唾液中的诱发仪 - 加尔夫斯特·(AS)中,在三个电极电池中在三个电极细胞中进行标本的抛光表面的开路电位(E-OCP)和电化学阻抗光谱(EIS)测量。将来自每组的标本浸入至和去离子水中七天。确定E-OCP,电荷转移电阻(R-α)值和释放离子(Mu G / cm(2)×7d)在不同的溶液中进行。用SEM / EDS观察样品表面。统计上分析结果。结果。 E-OCP值已移至随着时间的推移更积极的潜力。稳态E-OCP值高于低至低于以下,SB-SLM,SP2-MYS,SP2-EOS,RS-MLAB和ST-Pro。 60分钟后,RS-MLAB样本具有最高的R-alpha值,其次是SP2-MYS,SB-SLM,SP2-EOS和ST-Pro。在所有组中,离子释放在去离子水中的较高。结论。用MLS系统产生的CO-CR合金标本的耐腐蚀性差异很小;同时,所有标本对腐蚀性相当高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号