首页> 外文期刊>International endodontic journal >Cleaning of used rotary nickel‐titanium files in an ultrasonic bath by locally intensified acoustic cavitation
【24h】

Cleaning of used rotary nickel‐titanium files in an ultrasonic bath by locally intensified acoustic cavitation

机译:通过局部强化声空化清洁超声波浴中使用的旋转镍钛文件

获取原文
获取原文并翻译 | 示例

摘要

Abstract Aim To compare the pre‐sterilization cleaning of rotary Ni‐Ti files of different sizes previously used a. ex?vivo and b. clinically by a washer–disinfector, a regular ultrasonic bath, and the same ultrasonic bath in combination with a recently developed cavitation intensifying method. Methodology Two sets of two hundred rotary Ni‐Ti files, one previously used ex?vivo and another one used clinically, were collected from the undergraduate and postgraduate clinics of the Academic Centre for Dentistry Amsterdam ( ACTA ). The instruments were immersed in an enzymatic solution and subsequently cleaned either by a washer–disinfector, a regular ultrasonic bath combined with a glass beaker, the same bath combined with a beaker lined with two cavitation intensifying sheets or with two standard plastic sheets. The positive control consisted of used files that did not undergo any cleaning and the negative control included new unused files. The instruments were then stained to reveal remaining protein material and scored under a stereoscopic microscope. The results were analysed by nonparametric statistical tests (α?=?0.05). Results No significant difference was found between the combination of the ultrasonic bath and the regular glass beaker and the same ultrasonic bath with the beaker lined with the cavitation intensifying sheets. The washer–disinfector left significantly more debris compared to the latter group when clinically used files were evaluated ( P? ≤ ? 0.001). The effect of instrument size on cleaning was not consistent. Conclusion None of the tested methods was able to remove all residual protein material from the files; however, it could be noted that this study did not follow the reprocessing protocol provided by the manufacturer.
机译:摘要旨在比较先前使用的不同尺寸的旋转Ni-Ti文件的预灭菌清洁。例如,体内和b。通过垫圈消毒剂,常规超声浴和相同的超声浴结合最近开发的空化强化方法。方法论两组两组旋转NI-TI文件,先前用过的EX?体内和另一个临床上使用的另一个,从牙科阿姆斯特丹学术中心(Acta)的学术中心的本科和研究生诊所收集。将仪器浸入酶溶液中,随后通过垫圈消毒剂清洁,常规超声浴与玻璃烧杯结合,与烧杯相同的浴器,烧杯用两个空化强化片材或两个标准塑料片。正面控件由使用的使用文件组成,该文件不会发生任何清洁,并且负控包括新未使用的文件。然后染色该仪器以显示剩余的蛋白质材料并在立体显微镜下进行刻痕。通过非参数统计测试分析结果(α?= 0.05)。结果在超声浴和常规玻璃烧杯的组合和与烧杯中衬有空化增强片材的相同超声浴之间没有显着差异。当评估临床使用的文件时,垫圈 - 消毒剂与后一组相比,碎片明显更多的碎片(P?≤≤0.001)。仪器尺寸对清洁的影响并不一致。结论没有测试的方法能够从文件中除去所有残留的蛋白质;但是,可以注意到本研究没有遵循制造商提供的再加工协议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号