首页> 外文期刊>International endodontic journal >Fracture incidence of instruments from a single‐file reciprocating system by students in an endodontic graduate programme: a cross‐sectional retrospective study
【24h】

Fracture incidence of instruments from a single‐file reciprocating system by students in an endodontic graduate programme: a cross‐sectional retrospective study

机译:由学生在椎间型毕业程序中由单文件往复式系统的骨折发病率:横断面回顾性研究

获取原文
获取原文并翻译 | 示例
       

摘要

Abstract Aim To assess the fracture incidence of instruments from single‐file reciprocating systems when used by students in an endodontic graduate programme. Methodology Dental records and periapical radiographs of patients treated by students on an endodontic graduate programme using reciprocating systems were assessed. Data on tooth type, number of treated root canals, number of fractured instruments, fragment size, angle, radius, arc length and position of root canal curvature where fractures occurred were tabulated for analysis. The risk of fracture was calculated for each group of teeth, root canal and root thirds, whilst the incidence of fractures reported for the reciprocating systems was compared using the chi‐squared test at 5% significance level. Results Overall, 2056 root canals (826 teeth) from 810 patients were included. The incidence of fractured files from single‐file reciprocating systems in relation to a number of instrumented canals was 0.92%. Fracture rates of 0.84% and 0.93% were found in 830 and 1226 root canals instrumented with WaveOne and Reciproc systems, respectively. No significant differences were observed between the systems. The highest fracture rate was 52.6% in the mesiobuccal root of mandibular molars. The central angle, radius and arc length of the curvature of root canals where the instruments fractured ranged from 58° to 84°, from 1.7 to 7.2?mm and from 2.4 to 7.6?mm, respectively. Conclusion The use of WaveOne and Reciproc single‐file reciprocating systems in an endodontic graduate programme was associated with a low incidence of instrument fractures.
机译:摘要旨在评估单文件往复系统的仪器骨折发生率,当学生在胸前古代研究生课程中使用时。评估使用往复系统对学生治疗的患者治疗的患者的方法论牙科记录和恐慌射线照片进行了评估。牙齿类型的数据,处理的根管数,裂缝仪器数,碎片尺寸,角度,半径,弧长和根管曲率的位置,其中裂缝发生骨折的分析。针对每组牙齿,根管和根系三分,计算骨折的风险,同时使用在5%显着性水平下的奇方检验进行往复式系统报告的骨折的发生率。结果总体而言,包括810名患者的2056个根管(826齿)。与多个仪表运河相关的单文件往复系统的裂缝文件的发生率为0.92%。在830和1226个根部管中,分别发现了0.84%和0.93%的裂缝率分别与波通和互联系统仪表。在系统之间没有观察到显着差异。下颌摩尔骨磁性根的最高断裂率为52.6%。根系曲线曲率的中心角,半径和弧长,其中仪器断裂的范围为58°至84°,分别为1.7至7.2Ωmm和2.4至7.6Ωmm。结论Waveodonic Graduate程序中的WaveOc和Reciproc单文件往复系统的使用与仪器骨折的发病率低有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号