首页> 外文期刊>Internal medicine journal >Trends in the use of implantable cardioverter defibrillators in Australia: a 10-year nationwide study from 2000-2009.
【24h】

Trends in the use of implantable cardioverter defibrillators in Australia: a 10-year nationwide study from 2000-2009.

机译:澳大利亚使用植入式心脏病玻璃除颤器的趋势:2000 - 2009年的全国10年学习。

获取原文
获取原文并翻译 | 示例
           

摘要

Implantable cardioverter defibrillators (ICD) have been demonstrated to reduce mortality in survivors of life-threatening arrhythmias (secondary prevention) and in patients at increased risk of sudden cardiac death (primary prevention). Other nations have reported significant increases in ICD use in recent years.To investigate Australian nationwide trends of ICD procedures over a 10-year period (2000-2009).A retrospective analysis of the Australian Institute of Health and Welfare's National Hospital Morbidity Database was performed to determine the annual number of ICD implantation and replacement procedures between 2000 and 2009. Rates were calculated using Australian Bureau of Statistics data on the annual estimated population. Time trends in the yearly procedure number and rate were analysed using negative binomial regression models with comparisons made by age and sex.The number of new ICD implantations increased from 708 to 3198 procedures between 2000 and 2009. Replacement procedures increased from 290 to 1378. The implantation rate (per million) increased from 37.0 to 145.6 and the replacement rate from 15.1 to 62.7. When rates were adjusted for age and sex, the implantation rate increased annually by 15.8% and the replacement rate by 16.6% (P < 0.0001). Procedures occurred most commonly in men (implantations: 80.1%; replacements: 78.0%) between ages 70-79.ICD procedures increased significantly in Australia between 2000-2009. Despite these increases, other studies have suggested ICD devices are currently under-utilised. During the study period, males accounted for the majority of ICD procedures. While there are numerous reasons for this, it is not known if device under-use is more common in females.
机译:已证明植入式心脏除颤器(ICD)以减少危及生命心律失常(二级预防)和患者突然心脏死亡风险增加的死亡率(初级预防)。其他国家近年来据报道ICD使用量大。在10年期间调查澳大利亚全国范围内的ICD程序趋势(2000-2009)。对澳大利亚卫生和福利国家医院病理疾病数据库的回顾分析确定2000年至2009年期间的ICD植入和更换程序的年度数量。利用澳大利亚统计数据的年度估计人口计算。使用负二项式回归模型分析年度过程数量和速率的时间趋势与年龄和性别进行比较。新的ICD植入数量从2000年至2009年之间的708增加到3198个程序。更换程序从290增加到1378。该植入率(百万人)从37.0增加到145.6增加,替换率从15.1到62.7。当率调整年龄和性别时,植入率每年增加15.8%,更换率为16.6%(P <0.0001)。男性最常发生的程序(植入:80.1%;替代品:78.0%)在70-79岁之间,2000-2009之间的澳大利亚在澳大利亚增加了显着增加。尽管有这些增加,但其他研究表明ICD设备目前不利用。在研究期间,男性占大多数ICD程序。虽然这有很多原因,但如果设备欠用在女性中更常见,则不知道。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有