首页> 外文期刊>Archives of disease in childhood. Fetal and neonatal edition >3-lead electrocardiogram is more reliable than pulse oximetry to detect bradycardia during stabilisation at birth of very preterm infants
【24h】

3-lead electrocardiogram is more reliable than pulse oximetry to detect bradycardia during stabilisation at birth of very preterm infants

机译:3-铅心电图比脉搏血管血管更可靠,以检测非常早产儿稳定期间的心动过缓

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objectives Current neonatal resuscitation guidelines suggest the use of ECG in the delivery room (DR) to assess heart rate (HR). However, reliability of ECG compared with pulse oximetry (PO) in a situation of bradycardia has not been specifically investigated. The objective of the present study was to compare HR monitoring using ECG or PO in a situation of bradycardia (HR 100beats per minute (bpm)) during preterm stabilisation in the DR.