Detection of minute quantities of target antigens in serum samples (consisting of a mixture of proteins/biomolecules) can be achieved by enhancement of the capture efficiencies of heterogeneous immunosensors. An important process parameter which affects the capture of target analytes in such immunosensors is the pH of the solution as the target proteins present in the serum samples are charged molecules. Here, we investigated the capture of prostate-specific antigens (PSAs), first in a mixed-analyte system wherein the solution contained two other non-specific proteins along with the target analyte, using the surface plasmon resonance spectroscopy. There are no reports on the detection of antigens in a mixed system based on the optimization of the pH values of the carrier fluid, and this is the motivation of the present work. Further, we studied interference effects caused by the presence of these non-specific proteins in the mixed-analyte systems by artificially increasing the ratio of the interfering proteins to that of the target protein. Eventually PSA spiked into the rabbit serum samples was captured through the optimization of the pH of the solution. We could detect PSA in the serum samples when diluted to 100 times or more, where the amounts of other interfering proteins were similar to 66 times that of the amount of PSA. This study proposes a heterogeneous immunosensor to detect the target analytes in the diluted serum samples by tuning pH the of solution mixture, which can be utilized to detect disease biomarkers in serum samples.
机译:通过增强非均相免疫转变体的捕获效率,可以实现血清样品中的微小量靶抗原(由蛋白质/生物分子的混合物组成)。影响这种免疫转变体中目标分析物捕获的重要过程参数是溶液的pH,因为血清样品中存在的靶蛋白是带电分子。这里,我们研究了使用表面等离子体共振光谱法的混合分析物系统中的捕获前列腺特异性抗原(PSA),其中溶液含有另外两种其他非特异性蛋白质,以及靶分析物。基于载体流体的pH值的优化,没有关于在混合系统中检测抗原的报道,这是本作工作的动机。此外,通过人为地增加干扰蛋白与靶蛋白的比率,研究了通过在混合分析物系统中存在这些非特异性蛋白质引起的干扰效应。最终通过优化溶液的pH捕获到兔血清样品中的PSA。当稀释至100倍以上时,我们可以检测血清样品中的PSA,其中其他干扰蛋白的量类似于PSA的量的66倍。该研究提出了通过调节溶液混合物的pH调节溶液混合物来检测稀释的血清样品中的靶分析物的异质免疫传感器,其可用于检测血清样品中的疾病生物标志物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号