首页> 外文期刊>Annals of the American Thoracic Society >Wearable In-Ear Encephalography Sensor for Monitoring Sleep Preliminary Observations from Nap Studies
【24h】

Wearable In-Ear Encephalography Sensor for Monitoring Sleep Preliminary Observations from Nap Studies

机译:可穿戴式内侧脑传感器,用于监测睡眠研究的睡眠初步观察

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Rationale: To date, EEG is the only quantifiable measure of the neural changes that define sleep. Although it is used widely for clinical testing, scalp-electrode EEG is costly and is poorly tolerated by sleeping patients. Objectives: This was a pilot study to assess the agreement between EEG recordings obtained from a new ear-EEG sensor and those obtained simultaneously from standard scalp electrodes. Methods: Participants were four healthy men, 25 to 36 years of age. During naps, EEG tracings were recorded simultaneously from the ear sensor and from standard scalp electrodes. A clinical expert, blinded to the data collection, analyzed 30-second epochs of recordings from both devices, using standardized criteria. The agreement between scalp- and ear-recordings was assessed. Measurements and Main Results: We scored 360 epochs (scalp-EEG and ear-EEG), of which 254 (70.6%) were scored as non-REM sleep using scalp-EEG. The ear-EEG sensor had a sensitivity of 0.88 (95% confidence interval [CI], 0.82-0.92) and a specificity of 0.78 (95% CI, 0.70-0.84) in detecting N2/N3 sleep. The kappa coefficient between the scalp- and the ear-EEG was 0.65 (95% CI, 0.58-0.73). As a sleep monitor (all non-REM sleep stages vs. wake), the in-ear sensor had a sensitivity of 0.91 (95% CI, 0.87-0.94) and a specificity of 0.66 (95% CI, 0.56-0.75). The kappa coefficient was 0.60 (95% CI, 0.50-0.69). Conclusions: Substantial agreement was observed between recordings derived from a new ear-EEG sensor and conventional scalp electrodes on four healthy volunteers during daytime naps.
机译:理由:迄今为止,脑电图是睡眠睡眠的唯一可量化的衡量标准。虽然它被广泛用于临床测试,但是头皮电极脑电图昂贵并且通过睡眠患者耐受性差不多。目的:这是一个试点研究,以评估从新的耳机传感器获得的EEG录像与标准头皮电极同时获得的录音之间的协议。方法:参与者是四名健康的男性,25至36岁。在小睡期间,从耳传感器和标准头皮电极同时记录EEG描记。使用标准化标准,将临床专家蒙蔽了数据收集,分析了来自两种设备的30秒钟记录时代。评估头皮和耳机之间的协议。测量和主要结果:我们得分360时(Scalp-EEG和EAG),其中254(70.6%)使用ScalP-EEG作为非REM睡眠。耳机传感器的灵敏度为0.88(置信区间,0.82-0.92)的比例为0.88(95%,0.82-0.92),在检测N2 / N3睡眠中的特异性为0.78(95%CI,0.70-0.84)。头皮和耳朵之间的Kappa系数为0.65(95%CI,0.58-0.73)。作为睡眠监测器(所有非REM睡眠阶段与唤醒),耳内传感器的灵敏度为0.91(95%CI,0.87-0.94),特异性为0.66(95%CI,0.56-0.75)。 Kappa系数为0.60(95%CI,0.50-0.69)。结论:在白天小睡期间,在新的耳机传感器和传统的头皮电极和传统的头皮电极播出之间观察到大量协议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号