This study evaluates the performance of the disposable inhalable aerosol sampler (DIAS), a new sampler developed to be more cost-effective than the traditional inhalable particle samplers and comparable to the inhalable particle sampling convention. Forty-eight pairs of the DIAS prototype and the IOM sampler were utilized to collect copper exposure measurements (23 personal and 25 area) at an electrorefinery facility. The geometric mean (GM) value of ratios of exposure data (DIAS/IOM) was 1.1, while the GM of ratios (DIAS/IOM) was 1.6 for the area exposure data, revealing 84% of the ratios were greater than one. For both personal and area exposure data, the concordance correlation coefficient tests revealed significant disagreements between the two types of samplers and suggested precision as the source of the disagreement. The estimated mean concentration was higher for the DIAS compared that for the IOM for the area exposure data (p < 0.05), while the results were comparable for the personal exposure data (p = 0.49). Overall, the DIAS generated higher exposure results compared to the IOM sampler for the area exposures. For the personal exposures, the findings were inconclusive due to inconsistent results of factors aforementioned. This study is limited to one metal component (copper) of the dust at a worksite. To date, this is the first field evaluation using personal exposure data to test the performance of the DIAS and the second evaluation using area exposure data. Thus, it will be necessary to conduct additional field evaluations with various elements to further evaluate the performance of the DIAS. In addition, particle migration to the internal walls of the cap was observed during the transportation of collected samples to a laboratory for both sampler types (6.4% for the DIAS and 7.4% for the IOM). Occupational health and safety professionals should be aware of potential errors caused from transferring samples from a field to a laboratory and should be careful not to exclude particles collected on the caps.
机译:本研究评估了一次性可吸入气溶胶采样器(DiaS)的性能,该采样器开发出比传统的可吸入粒子采样器更具成本效益,并与可吸入的粒子采样约定相当。使用48对Dia型原型和IOM取样器,用于在电火舍设施中收集铜曝光测量(23个个人和25个区域)。几何平均值(GM)曝光数据(DIAS / IOM)比率为1.1,而GM的比率(DIAS / IOM)为面积暴露数据为1.6,揭示了84%的比率大于1。对于个人和面积曝光数据,一致性相关系数测试显示两种样品在两种类型的采样器之间的显着分歧,并提出了精度作为分歧的源。对于区域曝光数据的IOM(P <0.05)而言,估计平均浓度较高,而结果对于个人曝光数据(P = 0.49)。总体而言,与区域曝光的IOM采样器相比,DIA产生了更高的曝光结果。对于个人风险,由于上述因素不一致的结果,调查结果不确定。该研究仅限于工地上的灰尘的一个金属部件(铜)。迄今为止,这是使用个人曝光数据来测试DIA的性能和使用面积曝光数据来测试DIA的性能的第一个场地评估。因此,有必要使用各种元素进行额外的场评估,以进一步评估Dia的性能。另外,在将收集的样品运输到实验室的实验室(用于DIA的6.4%)期间观察到帽的内壁的颗粒迁移到两种样品中,并且IOM的7.4%)。职业健康和安全专业人员应该了解潜在的错误,从将样品转移到一个实验室,并应注意不要排除收集在帽子上的颗粒。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号