Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler

机译:在一次性可吸入的气溶胶采样器中评估增加的采样泵流量速率

获取原文
获取原文并翻译 | 示例

摘要

A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler's performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times.
机译:开发了一种新设计的低成本,一次性可吸入的气溶胶采样器,以评估工人个人暴露于可吸入颗粒。该采样器最初设计用于在10L / min以10L / min操作以提高样品质量,从而改善基于滤波器的方法的分析检测限值。计算流体动力学建模显示,采样器性能(相对于气溶胶吸入性标准)不会在2和10L / min的采样器流动中基本上不同。考虑到这一点,新设计的可吸入气溶胶采样器在风隧道中同时在2和10L / min流动的流动中进行测试。时装模特配备了6种取样器/泵组件(三个泵在2 L / min,在风隧道中运行的三个泵,三个泵),在风隧道内操作,以0.2米/秒操作,这已被显示为典型的室内工作场所风速。在单独的测试中,注射了四种不同的粒度,以确定采样器的性能与新的10L / min流量的性能显着不同于2L / min。使用Wilcoxon签名秩检验的可吸入质量浓度之间的比较发现,对于在测试的所有颗粒尺寸下,在10和2L / min下采样的颗粒浓度没有显着差异。我们的研究结果表明,这种新的气溶胶采样器是一种多功能工具,可以通过改善检测极限并允许缩短采样时间来改善练习工业卫生主义者的暴露评估能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号