...
首页> 外文期刊>Annals of Clinical and Laboratory Science: Official Journal of the Association of Clinical Scientists >Taking Advantage of Assay Harmonization, Biotin Interference in the LOCI Digoxin Assay Could Be Eliminated by Using the ADVIA Centaur Digoxin Assay
【24h】

Taking Advantage of Assay Harmonization, Biotin Interference in the LOCI Digoxin Assay Could Be Eliminated by Using the ADVIA Centaur Digoxin Assay

机译:利用测定协调,可以通过使用Advia Centaur Digoxin测定来消除位于座位蛋白测定中的生物素干扰

获取原文
获取原文并翻译 | 示例
           

摘要

Biotin at elevated concentration interferes with immunoassays that utilize biotin in assay design. We earlier reported interference of biotin in the luminescent oxygen channeling assay (LOCI) digoxin assay which utilizes biotinylated antibody against digoxin. However, the ADVIA Centaur digoxin assay, also manufactured by Siemens Diagnostics, does not utilize biotin in assay design. We hypothesized that if the LOCI and the ADVIA Centaur digoxin assay are harmonized, then interference of biotin in the LOCI digoxin assay could be eliminated by using the ADVIA Centaur digoxin assay. We analyzed 25 specimens from patients receiving digoxin using both assays to investigate harmonization between these two assays. Then aliquots of drug-free serum pool were supplemented with various biotin concentrations (range: 10 ng/mL to 2000 ng/mL) followed by measuring apparent digoxin levels using the ADVIA Centaur digoxin assay. In another set of experiments, aliquots of a serum digoxin pool were supplemented with biotin (10-2000 ng/mL) and digoxin concentrations were measured by the ADVIA Centaur digoxin assay. We observed an excellent correlation between digoxin values obtained by the LOCI digoxin assay (reference method) and the ADVIA Centaur digoxin assay (y = 1.0514 x+0.1083, r=0.99) indicating that both assays are harmonized. We did not observe any interference of biotin even at a highly elevated concentration of 2000 ng/mL with the ADVIA Centaur digoxin assay. We conclude that taking advantage of assay harmonization, interference of biotin in the LOCI digoxin assay can be eliminated by using the ADVIA Centaur digoxin assay.
机译:升高浓度的生物素干扰了在测定设计中使用生物素的免疫测定。我们之前报告了在发光氧气窜射法中的生物素干扰,其利用生物素化抗体对高氧蛋白的生物素化测定法。然而,由Siemens诊断制造的Advia Centaur Digoxin测定法不利用Biotin在测定设计中。我们假设如果基因座和Advia Centaur Digoxin测定进行协调,则可以通过使用Advia Centaur Digoxin测定法消除Biotin在基因砜蛋白酶测定中的干扰。我们使用两种测定分析从接受辛辛接受Digoxin的患者进行调查,以研究这两个测定之间的协调。然后用各种生物素浓度(范围:10ng / ml至2000ng / ml)补充等分试样的无药物血清池,然后使用Advia Centaur Digoxin测定测量表观高氧蛋白水平。在另一组实验中,补充有生物素(10-2000ng / ml)的血清顶辛池的等分试样,并通过Advia Centaur Digoxin测定法测量高辛浓度。我们观察到通过基因突蛋白测定(参考方法)获得的高辛值与Advia Centaur Digoxin测定(Y = 1.0514 x + 0.1083,r = 0.99)之间的优异相关性,表明两种测定都是协调的。我们甚至没有观察到生物素的任何干扰,即使在高度升高的2000ng / ml中,具有Advia Centaur Digoxin测定。我们得出结论,利用测定协调,可以通过使用Advia Centaur Digoxin测定来消除位于座位蛋白测定中的生物素干扰。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号