首页> 外文期刊>Annals of nuclear medicine >Usefulness of both PET/CT with F18-FDG and whole-body diffusion-weighted imaging in cancer screening: a preliminary report
【24h】

Usefulness of both PET/CT with F18-FDG and whole-body diffusion-weighted imaging in cancer screening: a preliminary report

机译:PET / CT在癌症筛查中具有F18-FDG和全身扩散加权成像的PET / CT的用性:初步报告

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

ObjectivePositron emission tomography/computed tomography (PET/CT) with fluorodeoxyglucose (F18-FDG) is useful for the detection of malignant lesions, including metastatic lesions, and this technique is widely used in cancer screening. However, this approach may occasionally yield false-positive and false-negative findings. At our PET center, to increase the accuracy of PET/CT, we use PET/CT and whole-body diffusion-weighted imaging (WB-DWI) together. This study aimed to assess the usefulness of this combination.MethodsWe examined 29 subjects with confirmed diagnosis. All of them had undergone PET/CT and WB-DWI on the same day. Twenty-seven of them also underwent ultrasonography, blood testing, and upper gastrointestinal series on the same day and two fecal occult blood tests on another day. WB-DWI was performed on a 1.5-T MRI unit with a b value of 0 and 800 or 1000s/mm(2). For all 29 cases, PET/CT and WB-DWI were classified to be positive or negative, and the diagnostic ability was calculated for each modality.ResultsAmong the 29 subjects, 17 had malignant tumors and 12 had benign tumors or no abnormalities. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of PET/CT were 65%, 25%, 55%, 33%, and 48%, respectively; while the corresponding values for WB-DWI were 59%, 100%, 100%, 63%, and 76%, respectively. By considering the result to be negative when PET/CT findings were positive but WB-DWI findings were negative, specificity increased from 25 to 100%, and accuracy increased from 48 to 76%. On the other hand, by considering the result to be positive when the findings of either PET/CT or WB-DWI were positive, sensitivity increased from 65 to 76%, and accuracy increased from 48 to 55%.ConclusionsOur results suggest that using both PET/CT and WB-DWI together can increase accuracy in cancer screening. However, this approach was not able to detect malignant lesions in some cases, indicating that there were limitations with imaging certain organs. Therefore, it is important to further understand the features of PET/CT and WB-DWI and use them appropriately for each organ. Additionally, given that the study sample was relatively small, further research is needed to validate these findings.
机译:具有氟脱氧葡萄糖(F18-FDG)的ObeseDhositron排放断层扫描/计算断层扫描(PET / CT)可用于检测恶性病变,包括转移性病变,并且该技术广泛用于癌症筛查。然而,这种方法可能偶尔会产生假阳性和假阴性的结果。在我们的宠物中心,提高PET / CT的准确性,我们将PET / CT和全身扩散加权成像(WB-DWI)一起使用。本研究旨在评估这种组合的有用性。乙二醇检查了29名受试者的诊断。所有这些都在同一天经历了PET / CT和WB-DWI。二十七名也经过超声检查,血液检测和上胃肠系列在同一天和两次粪便血液测试。 WB-DWI在1.5-T MRI单元上进行,B值为0和800或1000s / mm(2)。对于所有29例,PET / CT和WB-DWI被分类为阳性或阴性,并且针对每种型号计算诊断能力。案例among 29个受试者,17名恶性肿瘤和12种具有良性肿瘤或没有异常。 PET / CT的敏感性,特异性,阳性预测值(PPV),阴性预测值(NPV)和精度分别为65%,25%,55%,33%和48%;虽然WB-DWI的相应值分别为59%,100%,100%,63%和76%。当PET / CT发现为阳性但WB-DWI发现为阴性时,特异性从25%增加,精度从48增加到76%,从而增加。另一方面,考虑到PET / CT或WB-DWI的发现是阳性的结果,灵敏度从65增加到76%,精度从48增加到55%.Conclusionsour结果表明使用两者PET / CT和WB-DWI一起可以提高癌症筛查的准确性。然而,在某些情况下,这种方法无法检测恶性病变,表明对某些器官的成像有局限性。因此,重要的是进一步了解PET / CT和WB-DWI的特征,并为每个器官适当地使用它们。此外,鉴于研究样本相对较小,需要进一步的研究来验证这些发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号