RBC deformability measurement based on variations of pressure in multiple micropillar channels during blood delivery using a disposable air-compressed pump

机译:基于使用一次性空气压缩泵在血液递送过程中的多个微小硅通道中的压力变化的RBC可变形性测量

获取原文
获取原文并翻译 | 示例
           

摘要

Subpopulations of red blood cells (RBCs) are attributed to symptoms associated with hematological disorders. To detect differences in subpopulations of RBCs, RBC deformability has been considered as a promising label-free biomarker. To realize high throughput and a label-free approach, previous methods have required bulky syringe pumps for blood delivery and time-resolved micro-PIV techniques to obtain blood velocity fields. In this study, blood (approximate to 0.2 mL) is delivered using a disposable air-compressed pump. Subsequently, RBC deformability is quantified by analyzing the cell-to-liquid interface in the pressure channel () caused by successive clogging of RBCs in multiple micropillar channels. By averaging temporal variations in the intensity of captured images of the blood within the pressure channel for a specific duration, a normalized deformability index (DI) is defined to quantify RBC deformability. Through the operation of the disposable air-compressed pump, blood velocity is gradually reduced over time. As observed, RBC clogging in the micropillar channel led to an increase in the value of accompanied by fluctuations with the passage of time. A quantitative comparison of the proposed method (DI) against the previous method (V) is performed using blood samples composed of homogeneous and heterogeneous hardened RBCs. Upon performing linear regression analysis between DI and V, the coefficient of regression provides values as high as R-2 = 0.96-0.99 (i.e., P 0.001). Thus, DI could be effectively used to detect variations in the deformability of RBCs. Finally, the variation in RBC deformability is quantified over a storage period of 1 week. As a result, the values of these properties remained constant for a storage time of 1 week. The indices exhibited a significant relationship because regression analysis yielded a high value of R-2 = 0.7916 (i.e., P 0.001). In view of these experimental demonstrations, the proposed method of the normalized deformability index can be used to quantify RBC deformability, especially using a disposable air-compressed pump.
机译:红细胞(RBCS)的亚流程归因于与血液学疾病相关的症状。为了检测RBCS亚群的差异,RBC可变形性被认为是非无价值的无标记物。为了实现高吞吐量和无标签方法,先前的方法已经要求血液递送的庞大注射器泵和时间分辨的微PIV技术,以获得血液速度场。在该研究中,使用一次性空气压缩泵递送血液(近似为0.2mL)。随后,通过分析由多个微硅通道中的RBC连续堵塞引起的压力通道()中的细胞 - 液界面来量化RBC可变形性。通过对特定持续时间的压力通道内捕获血液的捕获图像强度的时间变化进行平均,定义了归一化的可变形性指数(DI)以量化RBC可变形性。通过一次性空气压缩泵的操作,随着时间的推移,血液速度逐渐减少。如图所示,RBC在微米通道中堵塞导致随着时间的推移而伴随波动的增加。使用由均相和非均相硬化的RBC组成的血液样品进行预先对先前方法(V)的预先比较方法(DI)的定量比较。在DI和V之间执行线性回归分析时,回归系数提供高达R-2 = 0.96-0.99(即P <0.001)的值。因此,可以有效地用于检测RBC可变形性的变化。最后,RBC可变形性的变化在1周的储存期间量化。结果,对于1周的存储时间,这些属性的值仍然是恒定的。索引表现出显着的关系,因为回归分析产生高值R-2 = 0.7916(即,P <0.001)。鉴于这些实验示范,归一化可变形性指数的提出方法可用于量化RBC可变形性,特别是使用一次性空气压缩泵。

著录项

  • 来源
    《Analytical methods》 |2018年第37期|共13页
  • 作者

    Kang Yang Jun;