首页> 外文期刊>Analytical Letters >Development of a Cobalt Electrode for the Determination of Phosphate in Soil Extracts and Comparison with Standard Methods
【24h】

Development of a Cobalt Electrode for the Determination of Phosphate in Soil Extracts and Comparison with Standard Methods

机译:钴电极的研制在土壤提取物中测定磷酸盐及标准方法的比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A phosphate-sensitive cobalt electrode was evaluated in detecting orthophosphate ions in ammonium lactate-acetic acid soil extracts. The dependence of the mixed potential of a cobalt electrode on concentration was investigated through potentiometry. The mechanism of detection is based on the consumption of a surface cobalt (II) oxide layer to form (Co-3(PO4)(2)), which leads to a concentration-dependent shift of the mixed potential. Two reference electrodes were evaluated: Ag/AgCl (3M) KCl and a platinum (Pt) wire. A linear response was observed using both reference electrodes. However, application of a Pt wire quasireference electrode increased the linear dynamic response range of the detector from 10-10(3)mgL(-1) or 10(-4)-10(-1)M (Ag/AgCl (3M) KCl) to 0.1-10(5)mgL(-1) or 10(-6)-10(1)M. In addition, the response time using the Pt wire was less than 5min compared to a minimum of 10min using Ag/AgCl (3M) KCl. There was close agreement between the response of the phosphate-sensitive cobalt electrode with a standard colorimetric method. As dissolved organic substances can potentially interfere with electrochemical techniques, an investigation into the use of a nonpolar resin for decolorization and removal of organic matter in soil extracts was performed and successfully used. The phosphate-sensitive cobalt electrode was found to be a fast method for the analysis of soil extracts with high sensitivity and selectivity. It has the potential to be developed into a sensor for the in situ measurement of phosphate in various environmental matrices.
机译:评价磷酸敏感的钴电极在检测乳酸铵 - 乙酸土壤提取物中的正磷酸盐离子中。通过电位测定,研究了钴电极的混合电位对浓度的依赖性。检测机制基于表面钴(II)氧化物层的消耗(CO-3(PO 4)(2)),这导致混合电位的浓度依赖性偏移。评估两个参考电极:Ag / AgCl(3M)KCl和铂(Pt)线。使用两个参考电极观察线性响应。但是,PT线Quasireferify电极的应用增加了检测器的线性动态响应范围从10-10(3)MGL(-1)或10(-4)-10(-1)M(Ag / AgCl(3M) KCl)至0.1-10(5)MgL(-1)或10(-6)-10(1)米。另外,与使用Ag / AgCl(3M)KCl相比,使用PT线的响应时间小于5min。磷酸盐敏感钴电极的响应与标准比色法之间密切一致。由于溶解的有机物质可能会干扰电化学技术,进行了对脱色,以在土壤提取物中使用非极性树脂的使用,并成功使用。发现磷酸敏感的钴电极是一种快速方法,用于分析具有高灵敏度和选择性的土壤提取物。它有可能开发成用于在各种环境基质中磷酸盐的原位测量的传感器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号