...
首页> 外文期刊>American Journal of Infection Control >State health department validations of central line–associated bloodstream infection events reported via the National Healthcare Safety Network
【24h】

State health department validations of central line–associated bloodstream infection events reported via the National Healthcare Safety Network

机译:国家卫生部门验证中央线相关的血流感染事件通过国家医疗保健安全网络报告

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BackgroundNumerous state health departments (SHDs) have validated central line–associated bloodstream infection (CLABSI) data, and results from these studies provide important insights into the accuracy of CLABSI reporting to the National Healthcare Safety Network (NHSN) and remediable shortcomings in adherence to the CLABSI definition and criteria. MethodsState CLABSI validation results were obtained from peer-reviewed publications, reports on SHD Web sites, and via personal communications with the SHD health care–associated infections coordinator. Data accuracy measures included pooled mean sensitivity, specificity, positive predictive value, and negative predictive value. Total CLABSI error rate was computed as the proportion of mismatches among total records reviewed. When available, reasons for CLABSI misclassification reported by SHDs were reviewed. ResultsAt least 23 SHDs that have completed CLABSI validations indicated sensitivity (pooled mean, 82.9%), specificity (pooled mean, 98.5%), positive predictive value (pooled mean, 94.1%), and negative predictive value (pooled mean, 95.9%) of CLABSI reporting. The pooled error rate of CLABSI reporting was 4.4%. Reasons for CLABSI misclassification included incorrect secondary bloodstream infection attribution, misapplication of CLABSI definition, missed case finding, applying clinical over surveillance definitions, misapplication of laboratory-confirmed bloodstream infection 2 definition, and misapplication of general NHSN definitions. ConclusionsCLABSI underreporting remains a major concern; validations conducted by SHDs provide an important impetus for improved reporting. SHDs are uniquely positioned to engage facilities in collaborative validation reviews that allow transparency, education, and relationship building.
机译:背景NOUNTIONE卫生部门(SHDS)已经验证了中央线相关的血流感染(CLABSI)数据,这些研究的结果提供了对国家医疗保健安全网络(NHSN)的准确性的重要见解,并遵守可靠的缺点clabsi定义和标准。 Photuert State Clabsi验证结果是从同行评审的出版物获得的,并通过与SHD医疗相关的感染协调员的个人沟通。数据准确度措施包括合并平均敏感性,特异性,阳性预测值和负预测值。 Clabsi错误率计算为复习总记录中不匹配的比例。当可用时,SHDS报告的CLABSI错误分类的原因进行了审查。结果至少23种已完成Clabsi验证的敏感性(合并平均值,82.9%),特异性(合并平均值,98.5%),阳性预测值(合并平均值,94.1%)和负预测值(合并平均值,95.9%) Clabsi报告。 Clabsi报告的汇总错误率为4.4%。 Clabsi错误分类的原因包括错误的继发性血流感染归因,Clabsi定义的缺陷,错过病例发现,临床过度监测定义,实验室证实血流感染的缺点定义,以及通用NHSN定义的误用。结论Clabsi疾病仍然是一个主要问题;由SHD进行的验证提供了改进报告的重要推动力。 SHDS独特地定位,以参与允许透明度,教育和关系建设的协同验证审查的设施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号