首页> 外文期刊>Anaesthesia: Journal of the Association of Anaesthetists of Great Britain and Ireland >A cadaver study comparing three fibreoptic-assisted techniques for converting a supraglottic airway to a cuffed tracheal tube
【24h】

A cadaver study comparing three fibreoptic-assisted techniques for converting a supraglottic airway to a cuffed tracheal tube

机译:一种尸体研究比较了三种纤维辅助技术将超透辅助技术转换为袖盘管

获取原文
获取原文并翻译 | 示例
           

摘要

After rescuing an airway with a supraglottic airway device, a method to convert it to a cuffed tracheal tube is often needed. The best method to do this has never been directly studied. We compared three techniques for conversion of a standard LMA((R)) Unique airway to a cuffed endotracheal tube using a fibrescope. The primary endpoint was time to intubation, with secondary endpoints of success rate, perceived difficulty and preferred technique. We also investigated the relationship between level of training and prior training and experience with the techniques on the primary outcome. The mean (95% CI) time to intubation using a direct tracheal tube technique of 37 (31-42) s was significantly shorter than either the Aintree intubation catheter technique at 70 (60-80) s, or a guidewire technique at 126 (110-141) s (p < 0.001). Most (13/24) participants rated the tracheal tube as their preferred technique, while 11/24 preferred the Aintree technique. In terms of perceived difficulty, 23/24, 21/24 and 9/24 participants rated the tracheal tube technique, Aintree technique and guidewire technique, respectively, as either very easy or easy. There was no relationship between prior training, prior experience or level of training on time to completion of any of the techniques. We conclude the tracheal tube and Aintree techniques both provide a rapid and easy method for conversion of a supraglottic airway device to a cuffed tracheal tube. The guidewire technique cannot be recommended.
机译:在用超透气道装置拯救气道后,通常需要将其转换为袖干气管的方法。这样做的最佳方法从未直接研究过。我们将三种技术与使用纤维镜头转换为转换标准LMA((r))独特的气道的技术。主要端点是插管的时间,具有成功率的次要终点,感知难度和优选的技术。我们还调查了培训水平与主要培训和主要结果技术之间的关系。使用直接气管管技术的平均值(95%CI)的插管时间为37(31-42)S的直接气管技术明显短于70(60-80)S的Aintree插管导管技术,或126( 110-141)S(p <0.001)。大多数(13/24)参与者将气管管作为优选的技术额定,而11/24优先于Aintree技术。就感知难度而言,23 / 24,21 / 24和9/24参与者分别额定气管管技术,Aintree技术和导丝技术,如非常容易或容易。事先培训,先前经验或培训水平之间没有任何关系,以完成任何技术。我们得出了气管管和Aintree技术,提供了一种快速简便的方法,用于将超级气道装置转换为袖干气管管。无法建议导丝技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号