首页> 外文期刊>American journal of dentistry >Incorporation of ZnCl2 into an etch-and-rinse adhesive system on flexural strength, degree of conversion and bond durability to caries-affected dentin
【24h】

Incorporation of ZnCl2 into an etch-and-rinse adhesive system on flexural strength, degree of conversion and bond durability to caries-affected dentin

机译:ZnCl2掺入蚀刻和冲洗粘合剂系统上,弯曲强度,转化程度和粘连的粘连受影响的牙本质

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To evaluate the effect of a zinc chloride (ZnCl2) solution (2% wt), incorporated into a two-step etch-and-rinse adhesive system (AS), on microtensile bond strength (mu TBS) to caries-affected dentin (CAD). Methods: First, the degree of conversion (DC) of the AS with and without the ZnCl2 solution was evaluated by Fourier transform infrared spectroscopy (FTIR). Second, beam-shaped samples (7 mm x 2 mm x 1 mm) were prepared with the AS containing the ZnCl2 solution to perform flexural strength (FS) tests. For mu TBS testing purposes, CAD surfaces were etched with phosphoric acid and randomly divided into three groups (n=10): ZnCl2 - AS with ZnCl2; NT (no treatment)-AS without ZnCl2; and CHX - pretreatment with 2% chlorhexidine solution. AS (Adper Single Bond 2) was applied according to the manufacturer's instructions, and resin composite restorations were built up. After 24 hours, the resindentin blocks were sectioned into specimens (0.8 mm 2 ), and then subjected to mu TBS testing immediately following, or after 6 or 12 months of water storage (WS). The adhesive interface was evaluated by scanning electron microscope. Both mu TBS and FS tests were performed using a universal testing machine (0.5 mm/minute). FS and DC data were submitted to the Student t-test, and mu TBS data were subjected to two-way ANOVA and Tukey's test (alpha= 0.05). Results: DC was not affected by ZnCl2 incorporation into AS (P= 0.2527). Higher FS values were obtained in the group with ZnCl2 added to AS. Regarding mu TBS, the mean of the NT group was statistically higher than that of the ZnCl2 or the CHX groups (P< 0.001), regardless of WS, but the latter groups did not differ from each other. mu TBS at 24 hours was statistically superior to that of 6 and 12 months of WS (P< 0.001).
机译:目的:评估氯化锌(ZnCl2)溶液(2%wt)的效果,掺入两步蚀刻和冲洗粘合剂系统(AS),对龋齿影响的牙本质粘连粘合强度(MU TBS) (CAD)。方法:首先,通过傅里叶变换红外光谱(FTIR)评价与ZnCl2溶液的转化率(DC)的程度评价。第二,用含有ZnCl2溶液制备梁形样品(7mm×2mm×1mm),以进行弯曲强度(FS)测试。对于MU TBS测试目的,用磷酸蚀刻CAD表面并随机分为三组(n = 10):ZnCl2 - 与ZnCl2一样; nt(无治疗) - 没有ZnCl2;和CHX - 用2%氯己定溶液进行预处理。据制造商的说明书应用(Adper单键2),并建立了树脂复合修复。 24小时后,将中断蛋白嵌段嵌入样品(0.8mm 2)中,然后立即进行MU TBS测试,或在储水(WS)的6或12个月后进行。通过扫描电子显微镜评估粘合剂界面。使用通用测试机(0.5毫米/分钟)进行MU TBS和FS测试。 FS和DC数据提交给学生T检验,MU TBS数据进行双向ANOVA和TUKEY的测试(alpha = 0.05)。结果:DC不受ZnCl2掺入的影响(P = 0.2527)。将ZnCl2添加到ZnCl 2中获得较高的FS值。关于MU TBS,NT组的平均值统计学上高于ZnCl2或CHX基团(P <0.001),无论WS如何,但后期彼此没有不同。 MU TBS在24小时的统计学上优于6和12个月的WS(P <0.001)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号