首页> 外文期刊>Acta Neurochirurgica >Integrity of dural closure after autologous platelet rich fibrin augmentation: an in vitro study
【24h】

Integrity of dural closure after autologous platelet rich fibrin augmentation: an in vitro study

机译:自体血小板富含纤维蛋白增强后的多云闭合的完整性:体外研究

获取原文
获取原文并翻译 | 示例
           

摘要

Background Watertight closure of the dura mater is fundamental in neurosurgery. Besides the classical suturing techniques, a variety of biomaterials have been proposed as sealants. Platelet rich fibrin (PRF) is an autologous biomaterial which can readily be obtained through low-speed centrifugation of patient's own blood. It is rich in fibrin, growth factors, leucocytes and cytokines and has shown adhesive properties while promoting the physiological wound healing process. In this study, we investigated the effect of applying PRF in reinforcing the watertight dura mater closure. Methods We created an in vitro testing device, where the watertight dura mater closure could be hydrostatically assessed. On 26 fresh harvested bovine dura maters, a standardised 20-mm incision was closed with a running suture, and the leak pressure was measured first without (primary leak pressure) and then with PRF augmentation (secondary leak pressure). The two groups of measurements have been statistically analysed with the Student's paired t test. Results The "running suture only group" had a leak pressure of 10.5 +/- 1.2 cmH2O (mean +/- SD) while the "PRF-augmented group" had a leak pressure of 47.2 +/- 2.6 cm H2O. This difference was statistically significant (p 4-fold increased leak pressure after failure of the initial standard running suture technique.
机译:背景水密闭合杜拉母体是神经外科的根本。除了经典缝合技术之外,已经提出了各种生物材料作为密封剂。富含抗纤维蛋白(PRF)的血小板是一种自体生物材料,可以通过低速离心患者自己的血液来易于获得。它富含纤维蛋白,生长因子,白细胞和细胞因子,并在促进生理伤口愈合过程的同时表现出粘合性能。在这项研究中,我们调查了PRF在加强防水硬脑膜闭合时的效果。方法我们创建了一种体外测试装置,可以互化水密硬母闭闭。在26个新鲜的收获的牛硬膜垫上,用行驶缝合封闭标准化的20mm切口,首先测量泄漏压力(初级泄漏压力),然后用PRF增强(次级泄漏压力)。两组测量与学生配对的T检验有统计分析。结果“运行缝合仅群体”的泄漏压力为10.5 +/- 1.2 CMH2O(平均+/-SD),而“PRF-Audmented Group”的泄漏压力为47.2 +/- 2.6厘米的H2O。这种差异在统计上显着(P 4折在初始标准运行缝合技术失败后增加泄漏压力。

著录项

  • 来源
    《Acta Neurochirurgica》 |2020年第4期|共7页
  • 作者单位

    Univ Freiburg Med Ctr Fac Med Neurozentrum Dept Neurosurg Breisacher Str 64 D-79106 Freiburg;

    Univ Freiburg Med Ctr Fac Med Neurozentrum Dept Neurosurg Breisacher Str 64 D-79106 Freiburg;

    Goethe Univ Frankfurt Frankfurt Oral Regenerat Med Clin Maxillofacial &

    Plast Surg Frankfurt;

    Univ Freiburg Med Ctr Fac Med Neurozentrum Dept Neurosurg Breisacher Str 64 D-79106 Freiburg;

    Univ Med Ctr Freiburg Dept Oral &

    Craniomaxillofacial Surg Freiburg Germany;

    Univ Freiburg Med Ctr Fac Med Dept Thorac Surg Freiburg Germany;

    Univ Freiburg Med Ctr Fac Med Neurozentrum Dept Neurosurg Breisacher Str 64 D-79106 Freiburg;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 头部及神经外科学;
  • 关键词

    Watertight Dural closure; Dural onlays; Autologous biomaterial; Neurosurgery;

    机译:防水多云闭合;多云缠结;自体生物材料;神经外科;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号