首页> 外文期刊>Cryogenics >Valve timing effect on the cooling performance of a 4 K pulse tube cooler
【24h】

Valve timing effect on the cooling performance of a 4 K pulse tube cooler

机译:气门正时对4 K脉冲管冷却器冷却性能的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Generally, a compressor together with a rotary valve system generates the pressure oscillation in GM-type cryocoolers. The timing of the rotary valve, which is one of the key operating parameters for cryocoolers, determines the relationship between intake and exhaust processes. A systematic investigation of valve timing effects on cooling performance of a two-stage 4 K pulse tube cooler (PTC) is reported. The experiments show that the optimization of valve timing can considerably improve the cooling performance for both stages. For the same PTC, a performance comparison for operation on different compressors with various input powers ranging from 0.5 to 6.0 kW is also presented.
机译:通常,压缩机和旋转阀系统一起在GM型低温冷却器中产生压力振荡。旋转阀的正时是低温冷却器的关键操作参数之一,它决定了进气和排气过程之间的关系。对气门正时对两级4 K脉冲管冷却器(PTC)的冷却性能的系统研究得到了报道。实验表明,优化气门正时可以显着改善两个阶段的冷却性能。对于相同的PTC,还介绍了在输入功率范围从0.5到6.0 kW的不同压缩机上运行的性能比较。