首页> 外文期刊>Current Eye Research >Repeatability of autofluorescence lifetime imaging at the human fundus in healthy volunteers
【24h】

Repeatability of autofluorescence lifetime imaging at the human fundus in healthy volunteers

机译:在健康志愿者的人眼底上自发荧光寿命成像的可重复性

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: We aim to evaluate the repeatability of a new fluorescence lifetime imaging (FLIM) technique which measures time-resolved autofluorescence to assess metabolism of the retina. Materials and methods: We performed FLIM with two spectral channels (channel 1: 490-560 nm and channel 2: 560-700 nm) on 10 healthy volunteers, with 10 replicates per volunteer. From the 30° fundus FLIM images, we selected three regions: the fovea, the optic disc and the papillo-macular bundle. For each channel in these regions, we determined an average multi-exponential approximation with three components, and the six resulting parameters, α1-α3 (amplitudes) and τ1-τ3 (fluorescence lifetimes), were analyzed in terms of the coefficient of variation (CV). Results: Repeatability was highest in the papillo-macular bundle, followed by the fovea and the optic disc. Repeatability was higher in channel 1 (mean CV of 7.9%) than in channel 2 (mean CV of 17.7%). The average CV for the diagnostically most relevant channel 1 and the most relevant parameters was as follows: τ1 (5.5%) and τ2 (4.7%) in the papillo-macular bundle, and τ1 (6.8%) and τ2 (6.9%) in the fovea. Conclusions: We demonstrated repeatability of FLIM measurement results within acceptable ranges of variation. Based on the detailed coefficients of variation, we derived recommendations for parameter ranges suitable for diagnostic applications.
机译:目的:我们的目标是评估新的荧光寿命成像(FLIM)技术的可重复性,所述荧光寿命成像(FLIM)技术测量时间分辨的自荧光,评估视网膜的代谢。材料和方法:在10个健康的志愿者上,我们用两个光谱通道(通道1:490-560nm和频道2:560-700nm)进行了FLIM,每志愿者10重复。从30°的眼底flim图像,我们选择了三个地区:Fovea,光盘和乳头黄斑束。对于这些区域中的每个通道,我们确定了三种组分的平均多指数近似,并且在变异系数方面分析了六个所得参数,α1-α3(幅度)和τ-τ3(荧光寿命)(简历)。结果:乳头黄斑束中的可重复性最高,其次是FOVEA和光盘。频道1的重复性高于通道2(平均CV)(平均CV为17.7%)。诊断上最相关的通道1和最相关参数的平均CV如下:乳头黄斑束中的τ1(5.5%)和τ2(4.7%),以及τ1(6.8%)和τ2(6.9%) fovea。结论:我们在可接受的变化范围内表现出脱脂测量结果的可重复性。基于详细的变体系数,我们推导出适用于诊断应用的参数范围的建议。

著录项

  • 来源
    《Current Eye Research》 |2013年第7期|共9页
  • 作者单位

    Institute of Biomedical Engineering and Informatics Ilmenau University of Technology Ilmenau;

    Institute of Biomedical Engineering and Informatics Ilmenau University of Technology Ilmenau;

    Institute of Biomedical Engineering and Informatics Ilmenau University of Technology Ilmenau;

    Institute of Biomedical Engineering and Informatics Ilmenau University of Technology Ilmenau;

    Department of Experimental Ophthalmology University of Jena Jena Germany;

    Department of Experimental Ophthalmology University of Jena Jena Germany;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 眼科学;
  • 关键词

    Eye; in vivo FLIM; Metabolic mapping; Retina;

    机译:眼睛;在体内flim;代谢映射;视网膜;