首页> 外文期刊>Cornea >Comparison of Visual Acuity Outcomes Between Nanothin Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty
【24h】

Comparison of Visual Acuity Outcomes Between Nanothin Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty

机译:纳米管剥离剥离自动内皮角膜术后视力结果的视力结果比较和DESCEMET膜内皮角膜术

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To compare the visual outcomes and complications between nanothin Descemet stripping automated endothelial keratoplasty (NT-DSAEK) and Descemet membrane endothelial keratoplasty (DMEK).Methods: A prospective comparative case series of 28 consecutive cases of NT-DSAEK (less than or equal to 50 pm) and DMEK was undertaken. Inclusion criteria were a diagnosis of Fuchs dystrophy, presence of pseudophakia, or planned combined cataract surgery/endothelial keratoplasty, with a minimum of 6-month follow-up. Exclusion criteria were any concurrent ocular comorbidities. Primary outcomes measures were best spectacle-corrected visual acuity (BSCVA) and complications.Results: Mean thickness of NT-DSAEK grafts was 41.0 ± 7.5 μm (range 26-50 μm). At 1 month postoperatively, the DMEK group had significantly better mean BSCVA of 0.18 ± 0.20 logarithm of the minimum angle of resolution (logMAR) (20/33) compared with 0.28 ±0.16 logMAR (20/40) for NT-NSAEK (P = 0.049). At 3, 6, and 12 months postoperatively, mean BSCVA was comparable between both groups [3 months: NT-DSAEK 0.17 ± 0.12 logMAR (20/30) versus DMEK 0.13 ± 0.17 (20/27), P= 0.31; 6 months: NT-DSAEK 0.11 ± 0.10 logMAR (20/26) versus DMEK 0.09 ±0.10 (20/25), P = 0.63; 12 months: NT-DSAEK 0.07 ± 0.09 logMAR (20/24) versus DMEK 0.07 ±0.11 logMAR (20/24), P = 0.95], Other than 1 NT-DSAEK graft that was successfully rebubbled, no other complications were encountered in either group.Conclusions: Compared with DMEK, NT-DSAEK provides comparable visual outcomes and complications rates.
机译:目的:比较纳米蛋白去除剥离自动内皮角膜形术(NT-dsaek)和Descremet膜内皮角膜术(DMEK)之间的视觉结果和并发症。方法:近期NT-dsaek连续28个潜在的比较案例系列(小于或等于下午5点)和DMEK进行了。纳入标准是福克斯营养不良,假期存在的缺陷营养不良,或计划组合性白内障手术/内皮角膜或内皮角膜术的诊断,至少为6个月的随访。排除标准是任何并发的眼镜。主要结果措施是最佳的眼镜校正的视力(BSCVA)和并发症。结果:NT-DSAEK移植物的平均厚度为41.0±7.5μm(范围26-50μm)。在术后1个月,DMEK组与NT-NSAK的0.28±0.16 logmar(20/40)相比,DMEK组的最小角度(Logmar)(20/33)的最小角度的BSCVA为0.18±0.20对数。(P = 0.049)。在术后3,6和12个月,两组之间的平均BSCVA相当[3个月:NT-DSAEK 0.17±0.12 logmar(20/30)与DMEK 0.13±0.17(20/27),P = 0.31; 6个月:NT-DSAEK 0.11±0.10 logmar(20/26)与DMEK 0.09±0.10(20/25),P = 0.63; 12个月:NT-DSAEK 0.07±0.09 logmar(20/24)与DMEK 0.07±0.11 logmar(20/24),p = 0.95],除了成功重建的1 nt-dsaek移植物之外,没有其他并发症无论是Group.conclusions:与DMEK相比,NT-DSAEK提供了可比的视觉结果和并发症率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号