The validity of different display monitors in the assessment of dental implant site dimensions in cone beam computed tomography images

机译:不同显示监视器在评估锥形束计算机断层扫描图像中的种植牙部位尺寸方面的有效性

获取原文
获取原文并翻译 | 示例
           

摘要

Objective. To determine if the differing contrast resolution of various LCD monitors affects the reliability or accuracy of measurements of proposed implant sites. Materials and methods. Edentulous areas of human dry skulls were marked with radiopaque markers in order to standardize the plane of the transverse cross-sections of the ridges and path of measurements. The skulls were imaged by a CBCT device and the images stored in proprietary format on the workstation. The data sets were then transferred, with the proprietary reformatting software, to two different laptops using CDs. Transverse cross-sectional images of the ridges were reformatted on all three computers and ridge dimensions were recorded using the linear measurement tool of the proprietary software. Ridge dimensions were recorded directly from the three different monitors by two observers and compared to measurements recorded directly from the bone. The measurement errors and intra-and inter-examiner reliability were calculated for each monitor and compared with each other. Results. Intra-and inter-examiner reliability scores for the measurements recorded from all three devices were very high and ranged between 0.993-0.999. The mean of the absolute errors was 0.55 mm for the workstation, 0.61 mm for laptop 1 and 0.68 mm for laptop 2. The absolute errors were statistically significant for all three monitors (p-value < 0.001), but there was no statistically significant difference between the absolute errors obtained from the three monitors. Conclusions. No differences in the reliability or accuracy of measurements of implant site dimensions were obtained using color LCD monitors with different contrast resolution capabilities.
机译:目的。要确定各种LCD监视器的不同对比度分辨率是否会影响建议植入位置的测量的可靠性或准确性。材料和方法。用不透射线的标记物标记人类干颅骨的相同区域,以使脊的横截面平面和测量路径标准化。头骨由CBCT设备成像,并将图像以专有格式存储在工作站上。然后使用专有的重新格式化软件将数据集使用CD传输到两台不同的笔记本电脑上。在所有三台计算机上重新格式化了脊的横截面图像,并使用专有软件的线性测量工具记录了脊的尺寸。两名观察员直接从三个不同的监视器记录了脊的尺寸,并将其与直接从骨骼记录的测量值进行了比较。计算每个监控器的测量误差以及检查者内部和检查者之间的可靠性,并将其相互比较。结果。从这三个设备记录的检查者内部和内部检查者的可靠性得分都非常高,范围在0.993-0.999之间。工作站的绝对误差的平均值为0.55毫米,笔记本电脑1的绝对误差的平均值为0.61毫米,笔记本电脑2的绝对误差的平均值为0.68毫米。所有三台显示器的绝对误差均具有统计学意义(p值<0.001),但差异无统计学意义从三个监视器获得的绝对误差之间。结论使用具有不同对比度分辨率功能的彩色LCD监视器,在植入部位尺寸的测量的可靠性或准确性方面没有差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号