首页> 外文期刊>Clinical rehabilitation >Effects of a 3D-printed orthosis compared to a low-temperature thermoplastic plate orthosis on wrist flexor spasticity in chronic hemiparetic stroke patients: a randomized controlled trial
【24h】

Effects of a 3D-printed orthosis compared to a low-temperature thermoplastic plate orthosis on wrist flexor spasticity in chronic hemiparetic stroke patients: a randomized controlled trial

机译:3D印刷矫形器与低温热塑性板矫形器对慢性半蠕虫中风患者腕部痉挛相比的影响:随机对照试验

获取原文
获取原文并翻译 | 示例
       

摘要

Objective: The aim of this study was to compare the effects of two kinds of wrist-hand orthosis on wrist flexor spasticity in chronic stroke patients. Design: This is a randomized controlled trial. Setting: The study was conducted in a rehabilitation center. Participants: A total of 40 chronic hemiparetic stroke patients with wrist flexor spasticity were involved in the study. Interventions: Patients were randomly assigned to either an experimental group (conventional rehabilitation therapy + 3D-printed orthosis, 20 patients) or a control group (conventional rehabilitation therapy + low-temperature thermoplastic plate orthosis, 20 patients). The time of wearing orthosis was about 4-8 hours per day for six weeks. Main measures: Primary outcome measure: Modified Ashworth Scale was assessed three times (at baseline, three weeks, and six weeks). Secondary outcome measures: passive range of motion, Fugl-Meyer Assessment score, visual analogue scale score, and the swelling score were assessed twice (at baseline and six weeks). The subjective feeling score was assessed at six weeks. Results: No significant difference was found between the two groups in the change of Modified Ashworth Scale scores at three weeks (15% versus 25%, P = 0.496). At six weeks, the Modified Ashworth Scale scores (65% versus 30%, P = 0.02), passive range of wrist extension (P < 0.001), ulnar deviation (P = 0.028), Fugl-Meyer Assessment scores (P < 0.001), and swelling scores (P < 0.001) showed significant changes between the experimental group and the control group. No significant difference was found between the two groups in the change of visual analogue scale scores (P = 0.637) and the subjective feeling scores (P = 0.243). Conclusion: 3D-printed orthosis showed greater changes than low-temperature thermoplastic plate orthosis in reducing spasticity and swelling, improving motor function of the wrist and passive range of wrist extension for stroke patients.
机译:目的:本研究的目的是比较两种腕上矫形器对慢性中风患者腕部屈肌痉挛的影响。设计:这是一个随机对照试验。环境:该研究在康复中心进行。参与者:研究中共有40例慢性半蠕动卒中患者患者参与了该研究。干预措施:患者被随机分配给实验组(常规康复治疗+ 3D印刷矫形器,20名患者)或对照组(常规康复治疗+低温热塑性板矫形器,20名患者)。穿着矫形器的时间约为每天4-8小时,六周。主要措施:主要成果措施:修饰的Ashworth Scale评估了三次(在基线,三周和六周)。次要结果措施:被动运动范围,Fugl-Meyer评估评分,视觉模拟比分和肿胀评分进行两次(基线和六周)。主观感觉得分在六周内进行评估。结果:在三周内改变修饰的Ashworth规模分数的两组之间没有发现显着差异(15%,比例为25%,P = 0.496)。在六周内,改良的Ashworth尺度评分(65%对30%,P = 0.02),腕延伸的无源范围(P <0.001),尺寸偏差(P = 0.028),Fugl-Meyer评估分数(P <0.001)并且肿胀评分(P <0.001)显示实验组和对照组之间的显着变化。在视觉模拟标度分数的变化中,两组之间没有发现显着差异(P = 0.637)和主观感觉得分(P = 0.243)。结论:3D印刷的矫形器显示出比低温热塑性板矫形器更大的变化,降低痉挛性和肿胀,提高手腕延伸的手腕和被动范围的动力范围。

著录项

  • 来源
    《Clinical rehabilitation》 |2020年第2期|共11页
  • 作者单位

    Shanghai Xuhui Cent Hosp Dept Rehabil 966 Huaihai Rd Shanghai 200031 Peoples R China;

    Shanghai Xuhui Cent Hosp Dept Rehabil 966 Huaihai Rd Shanghai 200031 Peoples R China;

    Shanghai Xuhui Cent Hosp Dept Rehabil 966 Huaihai Rd Shanghai 200031 Peoples R China;

    Shanghai Xuhui Cent Hosp Dept Rehabil 966 Huaihai Rd Shanghai 200031 Peoples R China;

    Shanghai Univ Sch Mechatron Engn &

    Automat 99 Shangda Rd Shanghai 200444 Peoples R China;

    Shanghai Univ Sch Mechatron Engn &

    Automat 99 Shangda Rd Shanghai 200444 Peoples R China;

    Shanghai Univ Sch Mechatron Engn &

    Automat 99 Shangda Rd Shanghai 200444 Peoples R China;

    Shanghai Xuhui Cent Hosp Dept Rehabil 966 Huaihai Rd Shanghai 200031 Peoples R China;

    Shanghai Xuhui Cent Hosp Dept Rehabil 966 Huaihai Rd Shanghai 200031 Peoples R China;

    Shanghai Xuhui Cent Hosp Dept Rehabil 966 Huaihai Rd Shanghai 200031 Peoples R China;

    Shanghai Univ Sch Mechatron Engn &

    Automat 99 Shangda Rd Shanghai 200444 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 康复医学;
  • 关键词

    Stroke rehabilitation; spasticity; printing; three-dimensional; orthotic devices;

    机译:中风康复;痉挛;印刷;三维;矫形器件;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号