...
首页> 外文期刊>Clinical chemistry and laboratory medicine: CCLM >Impact of assay design on test performance: Lessons learned from 25-hydroxyvitamin D
【24h】

Impact of assay design on test performance: Lessons learned from 25-hydroxyvitamin D

机译:测定设计对测试性能的影响:从25-羟基韦凡氨酸D中学到的经验教训

获取原文
获取原文并翻译 | 示例

摘要

Methods: 25-OHD was measured in 1236 samples using automated assays from Abbott, DiaSorin, Roche and Siemens. A subset of 362 samples had up to three liquid chromatography-tandem mass spectrometry 25-OHD analyses performed. 25-OHD2 recovery, dilution recovery, human anti-animal antibody (HAAA) interference, 3-epi-25-OHD3 cross-reactivity and precision of the automated assays were evaluated.Background: Current automated immunoassays vary significantly in many aspects of their design. This study sought to establish if the theoretical advantages and disadvantages associated with different design formats of automated 25-hydroxyvitamin D (25-OHD) assays are translated into variations in assay performance in practice.Results: The assay that combined release of 25-OHD with analyte capture in a single step showed the most accurate 25-OHD2 recovery and the best dilution recovery. The use of vitamin D binding protein (DBP) as the capture moiety was associated with 25-OHD2 under-recovery, a trend consistent with 3-epi-25-OHD3 cross-reactivity and immunity to HAAA interference. Assays using animal-derived antibodies did not show 3-epi-25-OHD3 cross-reactivity but were variably susceptible to HAAA interference. Not combining 25-OHD release and capture in one step and use of biotin-streptavidin interaction for solid phase separation were features of the assays with inferior accuracy for diluted samples. The assays that used a backfill assay format showed the best precision at high concentrations but this design did not guarantee precision at low 25-OHD concentrations.Conclusions: Variations in design among automated 25-OHD assays influence their performance characteristics. Consideration of the details of assay design is therefore important when selecting and validating new assays.
机译:方法:使用雅培,侨民,罗氏和西门子的自动测定,在1236个样品中测量25-OHD。 362样品的子集具有最多三种液相色谱 - 串联质谱25-OHD分析。 25-OHD2回收率,稀释回收,人抗动物抗体(HAAA)干扰,3-EPI-25-OHD3交叉反应性和自动测定的精度。背景:目前的自动化免疫测定在其设计的许多方面有很大差异很大。该研究寻求建立与自动化25-羟乙素D(25-OHD)测定的不同设计格式相关的理论优势和缺点,转化为实践中的测定性能的变化。结果:组合25-OHD释放的测定分析物在一步中捕获显示最精确的25-OHD2回收和最佳稀释恢复。作为捕获部分的使用维生素D结合蛋白(DBP)与25-OHD2的溢出相关,趋势与3-EPI-25-OHD3交叉反应性和哈瓦干涉的抗扰度一致。使用动物衍生的抗体的测定未显示出3-EPI-25-OHD3的交叉反应性,但是可变地易于衡量HAAA干扰。在一个步骤中不组合25-OHD释放和捕获,并且使用生物素 - 链霉抗生物素蛋白相互作用的固相分离是测定的特征,其具有较差的稀释样品的精度。使用回填测定格式的测定在高浓度下显示了最佳精度,但这种设计在低25-OHD浓度下没有保证精度。结论:自动化25-OHD测定中的设计变化影响它们的性能特征。因此,考虑测定设计的细节在选择和验证新测定时是重要的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号