...
首页> 外文期刊>Cytometry: The Journal of the Society for Analytical Cytology >The 'vanishing counting bead' phenomenon: Effect on absolute CD34+cell counting in phosphate-buffered. saline-diluted leukapheresis samples
【24h】

The 'vanishing counting bead' phenomenon: Effect on absolute CD34+cell counting in phosphate-buffered. saline-diluted leukapheresis samples

机译:“消失的计数珠”现象:对磷酸盐缓冲液中绝对CD34 +细胞计数的影响。盐水稀释的白细胞去除术样本

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Using a single-platform protocol to count absolute CD34+ hematopoietic precursor cell (HPC) levels with different reference microbeads, we recorded occasionally artifactually high CD34+ HPC counts in some leukapheresis bags, whereas dual-platform calculations were always consistent, Abnormal countings were observed only when phosphate-buffered saline (PBS)diluted leukapheresis samples were vortexed before analysis, A large series of blood samples analyzed similarly for CD34+ and CD4+ absolute counts did not show any sample or vortexing effect. With the volumetric absolute counting cytometer Partec-PAS, lower counts were also observed when different reference beads were vortexed before the instrument checking procedures. The counting abnormality was caused by a drop in microbead concentration (the "vanishing bead phenomenon"). This phenomenon reduced the total and relative bead event number in experimental and routine samples and in calibration procedures. This altered the bead denominator used to calculate absolute CD34+ HPC levels and it also reduced the concentration of standard calibration beads, Methods: Using the Partec-PAS to measure volumetrically the actual bead concentration, we studied the vanishing bead phenomenon. Different types of counting and reference microbeads were resuspended in media with or without proteins or cells. Replicates were submitted either to gentle manual mixing or to vortexing before counting. Results: Vortex agitation almost invariably induced the vanishing bead phenomenon when beads were resuspended in saline media or when an insufficient protein concentration was present, such as in diluted leukapheresis samples. Different bead types showed various degrees of sensitivity to vortexing. The bead disappearance was not caused by bubble formation or disruption. The addition of small amounts of protein completely prevented the vanishing bead phenomenon. The causative effect of the electrostatic charging of tube induced by vortexing is hypothesized. Conclusions: Sample suspensions containing counting beads for single-platform analysis must be resuspended in media with protein supplements to prevent the vanishing bead phenomenon and to ensure accurate counting. (C) 2001 Wiley-Liss, Inc. [References: 12]
机译:背景:使用单平台方案通过不同的参考微珠对CD34 +造血前体细胞(HPC)的绝对水平进行计数,我们偶尔在某些白细胞去除袋中记录了虚高的CD34 + HPC计数,而双平台计算始终保持一致,观察到异常计数只有在分析前将磷酸盐缓冲液(PBS)稀释的白细胞去除术样品涡旋涡旋处理时,大量类似分析CD34 +和CD4 +绝对计数的血液样本并没有显示出任何样品或涡旋效应。使用体积绝对计数细胞计数仪Partec-PAS,在仪器检查之前,先将不同的参比珠涡旋,然后观察到较低的计数。计数异常是由于微珠浓度下降(“消失珠现象”)引起的。这种现象减少了实验和常规样品以及校准程序中的总和相对珠粒事件数。这改变了用于计算CD34 + HPC绝对水平的分母,也降低了标准校准磁珠的浓度。方法:使用Partec-PAS量取实际磁珠浓度,我们研究了消失磁珠现象。将不同类型的计数和参考微珠重新悬浮在有或没有蛋白质或细胞的培养基中。在计数之前,将复制品进行温和的手动混合或涡旋。结果:当将珠子重新悬浮在盐介质中或当蛋白质浓度不足时(例如在稀释的白细胞分离术样品中),涡旋搅动几乎总是引起消失的珠子现象。不同的磁珠类型显示出不同程度的涡旋敏感性。珠粒消失不是由气泡形成或破裂引起的。少量蛋白质的添加完全防止了珠粒现象的消失。假设由涡旋引起的管的静电荷的原因。结论:用于单平台分析的含有计数珠的样品悬浮液必须重新悬浮在含有蛋白质补充剂的培养基中,以防止珠消失的现象并确保准确计数​​。 (C)2001 Wiley-Liss,Inc. [参考:12]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号