Purpose Although a maxillary nerve (MN) block reportedly provides satisfactory analgesia for midface surgery and chronic maxillofacial pain syndromes, a safe and reliable MN block technique has not been reported. The goal of this anatomical study was to quantify the various angles and depth of the block needle, as well as to evaluate the impact of volume on the extent of injectate spread that might influence anesthetic coverage and block-related complications. Methods Following an ultrasound-guided suprazygomatic MN block with dye injection, a dissection was performed in the pterygopalatine fossa (PPF) of four lightly embalmed cadaveric specimens. Half of the specimens were injected with 5 mL of dye, and the other half with 1 mL of dye. The needle depth was measured from the ultrasound images and using rubber markers. Following injection, dissection was performed to map the area of dye spread. Results The median [interquartile range (IQR)] distance from the skin to the PPF was 37 [36-43] mm and 47 [40-50] mm by ultrasound and rubber marker methods, respectively. The median [IQR] needle orientation was 14 [11-32] degrees inferiorly and 15 [10-17] degrees posteriorly. The PPF was consistently dyed in the 5 mL group, but sporadically dyed in the 1 mL group. In the 5 mL group, spread outside of the PPF was seen. Conclusions We showed that 5 mL of injectate far exceeds the capacity of the PPF, leading to drug spread outside of the PPF. Moreover, we found that 1 mL of injectate largely covered the nerve, suggesting a more efficacious and safer block procedure. This finding will need confirmation in future clinical studies.
机译:目的虽然据报道,较上颌神经(Mn)嵌段为中小学手术提供令人满意的镇痛,但仍未报告一种安全可靠的MN块技术。该解剖学研究的目标是量化块针的各种角度和深度,以及评估体积对可能影响麻醉覆盖率和嵌段相关并发症的注射扩散程度的影响。方法在具有染料注射的超声引导式超高凝血Mn嵌段后,在四个轻微残余的尸体样品的翼状甘露氨氨酸窝(PPF)中进行解剖。将一半的标本用5ml染料注射,另一半用1ml染料注射。从超声图像测量针深度并使用橡胶标记测量。在注射之后,进行解剖以映射染料涂抹面积。结果通过超声和​​橡胶标记方法,从皮肤到PPF的皮肤到PPF的中位数[胎面范围(IQR)]距离为37 [36-43] mm和47 [40-50] mm。中位[IQR]针向取向为14 [11-32]较小,下方15 [10-17]。 PPF在5mL基团中始终染色,但在1mL基团中偶尔染色。在5毫升组中,观察到PPF外部的扩散。结论我们表明,5毫升的注射率远远超过PPF的能力,导致药物扩散在PPF之外。此外,我们发现1毫升重新注射在很大程度上覆盖着神经,表明更有效和更安全的块手术。这一发现将在未来的临床研究中需要确认。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号