PurposeOxygen delivery through a Frova Intubating Introducer may be life-saving, and gas flow characteristics through this device have been described. Nevertheless, the feasibility of using a self-inflating resuscitation bag to deliver air or oxygen through this device has not been assessed. We compared volumes of air delivered and peak pressures generated with normal and maximal bimanual compression of a self-inflating resuscitation bag connected to a 70 cm Frova Intubating Introducer.MethodsIn this bench research study, the proximal end of the 14-F Frova Intubating Introducer was connected to the self-inflating resuscitation bag, and the distal end was connected to a flow analyzer fitted with an adult test lung. Thirty-five anesthesia health care providers (staff/trainees) squeezed the self-inflating resuscitation bag with three normal and three maximal bimanual compressions. Endpoints of interest included the delivered volume of air and generated peak pressure.ResultsNormal bimanual compression resulted in a smaller mean (standard deviation) volume of air and peak pressure compared with maximal bimanual compression [554 (131) vs 955 mL (121); mean difference - 400.4; 95% confidence interval [CI], - 441.8 to - 359.0; P < 0.001; and 22.0 (3.4) vs 41.8 cmH(2)O (13.3); mean difference - 19.7; 95% CI, - 23.5 to - 15.9; P < 0.001, respectively].ConclusionClinically useful, life-sustaining volumes of air can be delivered using normal and maximal bimanual compression of a self-inflating resuscitation bag connected to a 70 cm Frova Intubating Introducer.Trial registrationwww.clinicaltrials.gov (NCT02786355); registered 27 January, 2016.
机译:通过FROVA插管引线递送的indentoxygen可以是挽救寿命的,并且已经描述了通过该装置的气体流动特性。然而,尚未评估使用自充气复苏袋通过该装置提供空气或氧气的可行性。我们比较了具有正常和最大的生物压缩产生的空气输送和峰值压力,其自充气复苏袋连接到70cm Frova插管型材。这项工作台研究研究,14-f Frova插管介绍的近端是连接到自充气复苏袋,远端连接到装有成人试验肺的流量分析仪。三十五个麻醉保健提供者(员工/学员)挤压自充气复苏袋,具有三个正常和三个最大的肌肉按压。感兴趣的终点包括递送的空气量和产生的峰值压力。结果,与最大的Bimanual压缩相比,空气和峰值压力的较小平均值(标准偏差)的空气和峰值压力[554(131)Vs 955mL(121);平均差异 - 400.4; 95%置信区间[CI], - 441.8至-359.0; P <0.001;和22.0(3.4)vs 41.8 cmh(2)o(13.3);平均差异 - 19.7; 95%CI, - 23.5至 - 15.9; P <0.001分别] .Conclusionclinically有用,可以使用连接到70cm Frova插管导引器的自充气复苏袋的正常和最大的生物压缩来提供寿命维持体积.TRIAL EnginealWWW.ClinicTrials.gov(NCT02786355) ;注册2016年1月27日。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号