首页> 外文期刊>Brachytherapy >Skin dose estimation using virtual structures for Contura Multi-Lumen Balloon breast brachytherapy
【24h】

Skin dose estimation using virtual structures for Contura Multi-Lumen Balloon breast brachytherapy

机译:使用虚拟结构对Contura多腔气球乳房近距离放射治疗的皮肤剂量估算

获取原文
获取原文并翻译 | 示例
           

摘要

PurposeTo propose a workflow that uses ultrasound (US)-measured skin–balloon distances and virtual structure creations in the treatment planning system to evaluate the maximum skin dose for patients treated with Contura Multi-Lumen Balloon applicators. Methods and MaterialsTwenty-three patients were analyzed in this study. CT and US were used to investigate the interfractional skin–balloon distance variations. Virtual structures were created on the planning CT to predict the maximum skin doses. Fitted curves and its equation can be obtained from the skin–balloon distance vs. maximum skin dose plot using virtual structure information. The fidelity of US-measured skin distance and the skin dose prediction using virtual structures were assessed. ResultsThe differences between CT- and US-measured skin–balloon distances values had an average of ?0.5?±?1.1?mm (95% confidence interval [CI]?=??1.0 to 0.1?mm). Using virtual structure created on CT, the average difference between the predicted and the actual dose overlay maximum skin dose was ?1.7% (95% CI?=??3.0 to ?0.4%). Furthermore, when applying the US-measured skin distance values in the virtual structure trendline equation, the differences between predicted and actual maximum skin dose had an average of 0.7?±?6.4% (95% CI?=??2.3% to 3.7%). ConclusionsIt is possible to use US to observe interfraction skin–balloon distance variation to replace CT acquisition. With the proposed workflow, based on the creation of virtual structures defined on the planning CT- and US-measured skin–balloon distances, the maximum skin doses can be reasonably estimated.
机译:Purposeto提出了一种使用超声(美国)的工作流程,在治疗计划系统中使用超声(美国) - 射击性心球距离和虚拟结构创作,以评估用Contura多腔气球涂敷器治疗的患者的最大皮肤剂量。该研究分析了方法和物质患者。 CT和美国用于调查互动性的皮肤球囊距离变化。在规划CT上创建虚拟结构以预测最大皮肤剂量。使用虚拟结构信息,可以从皮肤球囊距离与最大皮肤剂量图获得拟合曲线及其等式。评估了我们测量的皮肤距离和使用虚拟结构的皮肤剂量预测的保真度。 CT-和美国测量的皮肤球囊距离值之间的差异平均值为0.5?±1.1?mm(95%置信区间[CI]?= ?? 1.0至0.1?mm)。使用在CT上创建的虚拟结构,预测和实际剂量覆盖的平均差异最大皮肤剂量是?1.7%(95%CI?= 3.0至0.4%)。此外,当在虚拟结构趋势线方程中应用美国测量的皮肤距离值时,预测和实际最大皮肤剂量之间的差异平均为0.7?±6.4%(95%CI?= ?? 2.3%至3.7% )。结论是可以使用我们观察交叉的表情球囊距离变化来替换CT采集。通过提出的工作流程,基于在规划CT和美国测量的皮肤球囊距离上定义的虚拟结构的创建,可以合理地估计最大的皮肤剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号