Objective: During dental radiography, the salivary and thyroid glands are at radiation risk. In 2007, the International Commission on Radiological Protection (ICRP) updated the methodology for determining the effective dose, and the salivary glands were assigned tissue-specific weighting factors for the first time. The aims of this study were to determine the absorbed dose to the organs and to calculate, applying the ICRP publication 103 tissue-weighting factors, the effective doses delivered during digital intraoral and panoramic radiography. Methods: Thermoluminescent dosemeter measurements were performed on an anthropomorphic head and neck phantom. The organ-absorbed doses were measured at 30 locations, representing different radiosensitive organs in the head and neck, and the effective dose was calculated according to the ICRP recommendations. Results: The salivary glands and the oral mucosa received the highest absorbed doses from both intraoral and panoramic radiography. The effective dose from a fullmouth intraoral examination was 15mSv and for panoramic radiography, the effective dose was in the range of 19-75 mSv, depending on the panoramic equipment used. Conclusion: The effective dose from a full-mouth intraoral examination is lower and that frompanoramic radiography is higher than previously reported. Clinicians should be aware of the higher effective dose delivered during panoramic radiography and the risk-benefit profile of this technique must be assessed for the individual patient.
机译:目的:在牙科造影期间,唾液和甲状腺均为辐射风险。 2007年,国际放射保护委员会(ICRP)更新了用于确定有效剂量的方法,并且唾液腺首次分配组织特异性加权因子。本研究的目的是将吸收剂量的吸收剂量确定为器官并计算,应用ICRP出版物103组织加权因子,在数字内和全景造影期间递送的有效剂量。方法:对拟蒽型头部和颈部模体进行热致发光剂量计测量。在30个位置测量器官吸收剂量,表示头部和颈部的不同放射筛器官,并且根据ICRP建议计算有效剂量。结果:唾液腺和口腔粘膜从口内和全景造影中获得最高的吸收剂量。来自满茅斯内检查的有效剂量为15MSV,对于全景放射照相,有效剂量在19-75msV的范围内,这取决于所使用的全景设备。结论:来自全口内检测的有效剂量较低,从血管辐射照相术高于先前报道。临床医生应了解全景射线照相期间递送的较高有效剂量,并且必须对个体患者进行评估该技术的风险益处概况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号